Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, t, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and F2 was searched.
259 parts are printed F2t
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
EDZV6.8BSOD-523Zener diode, 2 pins, ROHMZener diodeSOD-5232 pinsROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
EDZVFH6.8BSOD-523Zener diode, 2 pins, ROHMZener diodeSOD-5232 pinsROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- SOD-523
- Pins
- 2
- Details
- Zener Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
FFM102-MSOD-123Rectifier, 2 pins, Formosa MicrosemiRectifierSOD-1232 pinsFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- SOD-123
- Pins
- 2
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FFM102-NSOD-323Rectifier, 2 pins, Formosa MicrosemiRectifierSOD-3232 pinsFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- SOD-323
- Pins
- 2
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FR101WSOD-123FRectifier, 2 pins, Blue RocketRectifierSOD-123F2 pinsBlue Rocket
- What it is
- Rectifier
- Maker
- Blue Rocket
- Package
- SOD-123F
- Pins
- 2
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FR102LSOD-123FRectifier, 2 pins, HottechRectifierSOD-123F2 pinsHottech
- What it is
- Rectifier
- Maker
- Hottech
- Package
- SOD-123F
- Pins
- 2
- Details
- Fast-recovery rectifier, 100 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FR102WSOD-123FRectifier, 2 pins, RectronRectifierSOD-123F2 pinsRectron
- What it is
- Rectifier
- Maker
- Rectron
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
LBZT52B6V8T1GSOD-123Zener diode, 2 pins, LRCZener diodeSOD-1232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode, VZ Min 6.65 V, VZ Nom 6.8 V, VZ Max 6.93 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LBZX84B6V8LT1GSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ Min 6.65 V, VZ Nom 6.8 V, VZ Max 6.93 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LEDZ6.8BPT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 6.65 V, VZ Nom 6.8 V, VZ Max 6.93 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
5 more parts have no package on record
FFM102-MHRectifier, Formosa MicrosemiRectifierNot recordedNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FFM102-MSRectifier, Formosa MicrosemiRectifierNot recordedNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FFM102-MS-Q1Rectifier, Formosa MicrosemiRectifierNot recordedNot recordedFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
HFCN-880+RF filter, Mini-CircuitsRF filterNot recordedNot recordedMini-Circuits
- What it is
- RF filter
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LTCC filter, 950-3200 MHz
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
HFCN-880D+RF filter, Mini-CircuitsRF filterNot recordedNot recordedMini-Circuits
- What it is
- RF filter
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LTCC filter, 950-3200 MHz
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.