Skip to content

SMD code HD

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BZX585-C22SOD-523Zener diode, 2 pins, NexperiaZener diodeSOD-5232 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-523
    Pins
    2
    Pinout
    • 1 cathode
    • 2 anode
    Details
    22 V approx. ±5% voltage regulator (Zener) diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • CHEMD5GPSOT-563Complementary transistor pair (NPN and PNP), 6 pins, ChenmkoComplementary transistor pair (NPN and PNP)SOT-5636 pinsChenmko
    What it is
    Complementary transistor pair (NPN and PNP)
    Maker
    Chenmko
    Package
    SOT-563
    Pins
    6
    Details
    Dual Digital Silicon Transistor, 50 V, 100 mA
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor pair.

  • CPDH5V0P-HFSOD-523ESD protection diode, 2 pins, ComchipESD protection diodeSOD-5232 pinsComchip
    What it is
    ESD protection diode
    Maker
    Comchip
    Package
    SOD-523
    Pins
    2
    Details
    5 V bidirectional ESD protection diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • CPDVR5V0P-HFSOD-882ESD protection diode, 2 pins, ComchipESD protection diodeSOD-8822 pinsComchip
    What it is
    ESD protection diode
    Maker
    Comchip
    Package
    SOD-882
    Pins
    2
    Details
    5 V bidirectional ESD protection diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • ESDBVD5V0C2SOT-23ESD protection diode, 3 pins, JSCJESD protection diodeSOT-233 pinsJSCJ
    What it is
    ESD protection diode
    Maker
    JSCJ
    Package
    SOT-23
    Pins
    3
    Details
    ESD protection diode, VRWM 5 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • PP0720SCSMBTVS thyristor, 2 pins, ProTek DevicesTVS thyristorSMB2 pinsProTek Devices
    What it is
    TVS thyristor
    Maker
    ProTek Devices
    Package
    SMB
    Pins
    2
    Details
    Thyristor Surge Suppressor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 9 more parts have no package on record
    • HSP061-8M16ESD protection diode, STMicroelectronicsESD protection diodeNot recordedNot recordedSTMicroelectronics
      What it is
      ESD protection diode
      Maker
      STMicroelectronics
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • KTC3535TNPN transistor, KECNPN transistorNot recordedNot recordedKEC
      What it is
      NPN transistor
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: NPN transistor.

    • LFCN-7200+RF filter, Mini-CircuitsRF filterNot recordedNot recordedMini-Circuits
      What it is
      RF filter
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LTCC filter
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

    • LFCN-7200D+RF filter, Mini-CircuitsRF filterNot recordedNot recordedMini-Circuits
      What it is
      RF filter
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LTCC filter, DC-7200 MHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

    • MM5Z5V6BZener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • MM5Z5V6B-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Zener diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • NCP145AMX120LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage Regulator, Bias Rail CMOS, Very Low Dropout, 500 mA
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCP177BMX110LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear Voltage Regulator - Fast Transient Response, Enable
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • NCP186BMX180LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LDO Regulator - Fast Transient Response Low Voltage
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor pair

Diode range, part lifted. Test each transistor on its own pins, as the datasheet's pinout gives them.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

NPN transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as HD

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 3 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.