Skip to content

SMD code K110

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

K110 on a chip resistor

110 Ω

110 Ω resistor

The K is both the decimal point and the multiplier: 110 Ω.

Check it with a meter

Lift one end and measure across it. A good one reads 110 Ω. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 110 Ω on the board is a fault. Open, or well above 110 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 110 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (SOD-123F, MSOP-8, SMA), K110 is a part code instead. Those parts are listed below.

8 parts are printed K110

Not sure which one you have?

Answer up to 4 quick questions and these 8 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • DS110WSOD-123FSchottky diode, 2 pins, YFWSchottky diodeSOD-123F2 pinsYFW
    What it is
    Schottky diode
    Maker
    YFW
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • FM1100-MFLSOD-123FSchottky diode, 2 pins, Formosa MicrosemiSchottky diodeSOD-123F2 pinsFormosa Microsemi
    What it is
    Schottky diode
    Maker
    Formosa Microsemi
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • K110SDSOD-123F2 pins, YFWNot recordedSOD-123F2 pinsYFW
    What it is
    Not recorded
    Maker
    YFW
    Package
    SOD-123F
    Pins
    2
    Details
    Thyristor surge protector (TSS)
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: This part.

  • TSV620AILTSOT-23-6Operational amplifier, 6 pins, STMicroelectronicsOperational amplifierSOT-23-66 pinsSTMicroelectronics
    What it is
    Operational amplifier
    Maker
    STMicroelectronics
    Package
    SOT-23-6
    Pins
    6
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • TSV632ILTSOT-23-8Operational amplifier, 8 pins, STMicroelectronicsOperational amplifierSOT-23-88 pinsSTMicroelectronics
    What it is
    Operational amplifier
    Maker
    STMicroelectronics
    Package
    SOT-23-8
    Pins
    8
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • TSV632ISTMSOP-8Operational amplifier, 8 pins, STMicroelectronicsOperational amplifierMSOP-88 pinsSTMicroelectronics
    What it is
    Operational amplifier
    Maker
    STMicroelectronics
    Package
    MSOP-8
    Pins
    8
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • TSV6191ILTSOT-23-5Operational amplifier, 5 pins, STMicroelectronicsOperational amplifierSOT-23-55 pinsSTMicroelectronics
    What it is
    Operational amplifier
    Maker
    STMicroelectronics
    Package
    SOT-23-5
    Pins
    5
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • K1100S1URPSMA2 pins, LittelfuseNot recordedSMA2 pinsLittelfuse
    What it is
    Not recorded
    Maker
    Littelfuse
    Package
    SMA
    Pins
    2
    Details
    Silicon unilateral voltage triggered switch: Vbr=104..118V, Vrwm=90V, Ipp=120A(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.