SMD code KN in SOT-23
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
17 parts in SOT-23 are printed KN
Not sure which one you have?
Answer up to 4 quick questions and these 44 parts are ranked, with a meter test that settles it. It works on a dead part too.
all SOT-23, 3 pins. What differs:
2SK3018SOT-23N-channel MOSFET, HXYN-channel MOSFETHXY
- What it is
- N-channel MOSFET
- Maker
- HXY
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
BZX84C16CC-HFSOT-23Zener diode, ComchipZener diodeComchip
- What it is
- Zener diode
- Maker
- Comchip
- Package
- SOT-23
- Pins
- 3
- Details
- 16 V 0.35 mW zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
FMOS2SK3018-HSOT-23MOSFET, Formosa MicrosemiMOSFETFormosa Microsemi
- What it is
- MOSFET
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: MOSFET.
FMOS2SK3018-Q1-HSOT-23MOSFET, Formosa MicrosemiMOSFETFormosa Microsemi
- What it is
- MOSFET
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: MOSFET.
FMOSBSS138K1-HSOT-23MOSFET, Formosa MicrosemiMOSFETFormosa Microsemi
- What it is
- MOSFET
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: MOSFET.
GSFC0500SOT-23N-channel MOSFET, Good-ArkN-channel MOSFETGood-Ark
- What it is
- N-channel MOSFET
- Maker
- Good-Ark
- Package
- SOT-23
- Pins
- 3
- Details
- N-channel MOSFET, 50 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
L2SK3018WT1GSOT-23N-channel MOSFET, HXYN-channel MOSFETHXY
- What it is
- N-channel MOSFET
- Maker
- HXY
- Package
- SOT-23
- Pins
- 3
- Details
- N-channel MOSFET, 30 V, 0.1 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
L2SK3019LT1GSOT-23N-channel MOSFET, LRCN-channel MOSFETLRC
- What it is
- N-channel MOSFET
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- MOSFET, N-Channel(with ESD), VDSS 30 V, VGS 20 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
PMV48XPSOT-23P-channel MOSFET, NexperiaP-channel MOSFETNexperia
- What it is
- P-channel MOSFET
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- 20 V, 3.5 A P-channel Trench MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
S-L2SK3019LT1GSOT-23N-channel MOSFET, LRCN-channel MOSFETLRC
- What it is
- N-channel MOSFET
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- MOSFET, N-Channel(with ESD), VDSS 30 V, VGS 20 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
2SC4983SOT-23BelNot recordedBel
- What it is
- Not recorded
- Maker
- Bel
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: AF, Amp, 15V, 200mA, 250mW, B=135..270, 200MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SJ305SOT-23Sanyo ElectricNot recordedSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- SOT-23
- Pins
- 3
- Details
- p-MOS*-e: V-MOS, 30V, 200mA, <4Ω(0,05A)
- Source
- Published code list
Is it dead? The meter test is below: This part.
BZX84C16CCSOT-23Zener diode, JinYu semiconductorZener diodeJinYu semiconductor
- What it is
- Zener diode
- Maker
- JinYu semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode: Dual, 15.3..17.1V, Zzt=40, Izt=5mA, 350mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
DDZX5V6BSOT-23Zener diode, Diodes IncorporatedZener diodeDiodes Incorporated
- What it is
- Zener diode
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- Z-diode: 5,6V±2,5%, 500mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
DZ23C16SOT-23Zener diode, Luguang Electronic TechnologyZener diodeLuguang Electronic Technology
- What it is
- Zener diode
- Maker
- Luguang Electronic Technology
- Package
- SOT-23
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with KN
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 47 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.