Skip to content

SMD code LFW in DFN

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

1 part in DFN is printed LFW

Not sure which one you have?

Answer up to 4 quick questions and these 2 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • SQ24802K2DFDDFNSilergyNot recordedSilergy
    What it is
    Load switch
    Maker
    Silergy
    Package
    DFN
    Pins
    Not recorded
    Details
    4.2V to 16V, 5A, 31mΩ eFuse with Over-voltage Protection
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • 1 more part has no package on record. Nothing rules it out, so it stays.
    • ADP2120ACPZ-2.5-R710 pins, Analog Devices10 pinsAnalog Devices
      What it is
      Not recorded
      Maker
      Analog Devices
      Package
      Not recorded
      Pins
      10
      Details
      equivalent [2.5V DC]
      Source
      Published code list

      Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as LFW

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with LFW

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.