Skip to content

SMD code M8t

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

The last letter, t, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and M8 was searched.

125 parts are printed M8t

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BL8554CB3TR38SOT-23LDO regulator, 3 pins, Shanghai BellingLDO regulatorSOT-233 pinsShanghai Belling
    What it is
    LDO regulator
    Maker
    Shanghai Belling
    Package
    SOT-23
    Pins
    3
    Details
    Linear voltage regulator IC: LDO, 3.8V±2%, 300mA
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • BL8554CB5ATR18SOT-23-5LDO regulator, 5 pins, Shanghai BellingLDO regulatorSOT-23-55 pinsShanghai Belling
    What it is
    LDO regulator
    Maker
    Shanghai Belling
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 1.8V±2%, 300mA. +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • BL8554CB5ATR28SOT-23-5LDO regulator, 5 pins, Shanghai BellingLDO regulatorSOT-23-55 pinsShanghai Belling
    What it is
    LDO regulator
    Maker
    Shanghai Belling
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 2.8V±2%, 300mA. +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • BL8554CB5ATR38SOT-23-5LDO regulator, 5 pins, Shanghai BellingLDO regulatorSOT-23-55 pinsShanghai Belling
    What it is
    LDO regulator
    Maker
    Shanghai Belling
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 3.8V±2%, 300mA. +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • BL8554CB5BTR18SOT-23-5LDO regulator, 5 pins, Shanghai BellingLDO regulatorSOT-23-55 pinsShanghai Belling
    What it is
    LDO regulator
    Maker
    Shanghai Belling
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 1.8V±2%, 300mA. +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • BL8554CB5BTR28SOT-23-5LDO regulator, 5 pins, Shanghai BellingLDO regulatorSOT-23-55 pinsShanghai Belling
    What it is
    LDO regulator
    Maker
    Shanghai Belling
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 2.8V±2%, 300mA. +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • BL8554CB5BTR38SOT-23-5LDO regulator, 5 pins, Shanghai BellingLDO regulatorSOT-23-55 pinsShanghai Belling
    What it is
    LDO regulator
    Maker
    Shanghai Belling
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 3.8V±2%, 300mA. +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • BSH103SOT-233 pins, NexperiaNot recordedSOT-233 pinsNexperia
    What it is
    Not recorded
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Details
    n-MOS-e: V-MOS, LogL, 30V, 0,85A, <0,5Ω
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • BSN20SOT-23N-channel MOSFET, 3 pinsN-channel MOSFETSOT-233 pinsNot recorded
    What it is
    N-channel MOSFET
    Maker
    Not recorded
    Package
    SOT-23
    Pins
    3
    Details
    N-channel MOSFET, 50 V, 0.5 A
    Source
    Published code list

    Is it dead? The meter test is below: N-channel MOSFET.

  • BSN20WSOT-3233 pins, NexperiaNot recordedSOT-3233 pinsNexperia
    What it is
    Not recorded
    Maker
    Nexperia
    Package
    SOT-323
    Pins
    3
    Details
    n-MOS*-e: Sw, LogL, 50V, 100mA, 830mW, 8/15ns, 15Ω(100mA)
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • BSS66RSOT-233 pins, Diodes IncorporatedNot recordedSOT-233 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: Sw, 60V, 100mA, 330mW, B=50..150, >250MHz
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • BZT52C8V2WTSOD-523Zener diode, 2 pins, Taitron ComponentsZener diodeSOD-5232 pinsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOD-523
    Pins
    2
    Details
    SMD Zener Diodes (Two Terminals) - 200mW
    Source
    An older or alternative marking, from a published code list

    Is it dead? The meter test is below: Zener diode.

  • BZX84C18TSOT-523Zener diode, 3 pins, Silicon-Based TechnologyZener diodeSOT-5233 pinsSilicon-Based Technology
    What it is
    Zener diode
    Maker
    Silicon-Based Technology
    Package
    SOT-523
    Pins
    3
    Details
    zener 150mW 18V
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • CMOZ4L7SOD-523Zener diode, 2 pins, Central SemiconductorZener diodeSOD-5232 pinsCentral Semiconductor
    What it is
    Zener diode
    Maker
    Central Semiconductor
    Package
    SOD-523
    Pins
    2
    Details
    Z-diode: 4.47..4.94V, Izt=0.25mA, Zzt=1500Ω, 250mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • 1 more part has no package on record
    • BU1JUB3WGLDO regulator, ROHMLDO regulatorNot recordedNot recordedROHM
      What it is
      LDO regulator
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 1.85V±1%, 360mA, +CE
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

N-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.