Skip to content

SMD code N- in SOD-523

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

15 parts in SOD-523 are printed N-

Not sure which one you have?

Answer up to 4 quick questions and these 46 parts are ranked, with a meter test that settles it. It works on a dead part too.

all SOD-523, 2 pins. What differs:

  • BAR65-02VSOD-523PIN diode, InfineonPIN diodeInfineon
    What it is
    PIN diode
    Maker
    Infineon
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PIN diode or varicap.

  • BB181SOD-523Varicap diode, NXPVaricap diodeNXP
    What it is
    Varicap diode
    Maker
    NXP
    Package
    SOD-523
    Pins
    2
    Details
    VHF variable capacitance diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PIN diode or varicap.

  • CH651S-40GPSOD-523Schottky diode, ChenmkoSchottky diodeChenmko
    What it is
    Schottky diode
    Maker
    Chenmko
    Package
    SOD-523
    Pins
    2
    Details
    SCHOTTKY BARRIER DIODE, 40 V, 0.75 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • RB531S-30SOD-523Schottky diode, Galaxy MicroelectronicsSchottky diodeGalaxy Microelectronics
    What it is
    Schottky diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-523
    Pins
    2
    Details
    0.1A, 30V, Surface Mount Small Signal Schottky Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • RB531SM-30SOD-523Schottky diode, ROHMSchottky diodeROHM
    What it is
    Schottky diode
    Maker
    ROHM
    Package
    SOD-523
    Pins
    2
    Details
    Schottky Barrier Diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • RB531SM-30FHSOD-523Schottky diode, ROHMSchottky diodeROHM
    What it is
    Schottky diode
    Maker
    ROHM
    Package
    SOD-523
    Pins
    2
    Details
    Schottky Barrier Diode (AEC-Q101 qualified)
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • TRB531S-30SOD-523Schottky diode, Galaxy MicroelectronicsSchottky diodeGalaxy Microelectronics
    What it is
    Schottky diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-523
    Pins
    2
    Details
    0.1A, 30V, Surface Mount Small Signal Schottky Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • VCUT0714A02VSOD-523ESD protection diode, VishayESD protection diodeVishay
    What it is
    ESD protection diode
    Maker
    Vishay
    Package
    SOD-523
    Pins
    2
    Details
    Bidirectional Asymmetrical (BiAs) Single Line ESD-Protection Diode in SOD-523
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • BAT15-02VSOD-523Schottky diode, InfineonSchottky diodeInfineon
    What it is
    Schottky diode
    Maker
    Infineon
    Package
    SOD-523
    Pins
    2
    Details
    Si-diode: Schottky, DBS-mix, 4V, 100mA, <12GHz, <0,35pF
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • CH651S-40PTSOD-523Chenmko EnterpriseNot recordedChenmko Enterprise
    What it is
    Not recorded
    Maker
    Chenmko Enterprise
    Package
    SOD-523
    Pins
    2
    Details
    Diode: SBD, 40V, 750mA, Vf<0.7V(750mA)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • MA2S357SOD-523PanasonicNot recordedPanasonic
    What it is
    Not recorded
    Maker
    Panasonic
    Package
    SOD-523
    Pins
    2
    Details
    Capacitance diode: CATV, 34V, 58/3.5pF(0/17V), 0.54(470MHz)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • MAZS047SOD-523PanNot recordedPan
    What it is
    Not recorded
    Maker
    Pan
    Package
    SOD-523
    Pins
    2
    Details
    Z-diode: 4,4..5V, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • MAZS0470LSOD-523PanNot recordedPan
    What it is
    Not recorded
    Maker
    Pan
    Package
    SOD-523
    Pins
    2
    Details
    Z-diode: 4,45..4,69V, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • MMSZ5234BPTSOD-523Zener diode, Chenmko EnterpriseZener diodeChenmko Enterprise
    What it is
    Zener diode
    Maker
    Chenmko Enterprise
    Package
    SOD-523
    Pins
    2
    Details
    Zener diode: 6.2V±5%, Izt=20mA, Zzt=7, 225mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • MMSZ5263BPTSOD-523Zener diode, Chenmko EnterpriseZener diodeChenmko Enterprise
    What it is
    Zener diode
    Maker
    Chenmko Enterprise
    Package
    SOD-523
    Pins
    2
    Details
    Zener diode: 56V±5%, Izt=2.2mA, Zzt=150, 225mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as N-

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.