SMD code N3010
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.
N3010 on a chip capacitor
301 pF
301 pF capacitor
The n is both the decimal point and the unit: 301 pF.
Check it with a meter
Lift one end and measure it on a capacitance range. A good one reads close to 301 pF. In circuit the meter also sees everything connected across it, so the reading means little until it is out. A failed one usually reads near 0 Ω, or a steady low resistance, on the ohms range, often from a crack. On the board a shorted capacitor shorts its whole rail. A failed reading does not change what to fit: the marking still says 301 pF.
On a transistor or diode body, N3010 is a part code instead. Those parts are listed below.
The only part printed N3010 in our tables
CJMN3010
- What it is
- N-channel MOSFET
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- MOSFET, N-channel, 30 V, 10 A
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with N3010
For a marking with its end worn or burnt off. Each code has a page of its own.
Open this in the search to correct a character or try another package.