The last letter, s, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and PP was searched.
115 parts are printed PPs
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
1.5SMBJ160AASMBTVS diode, 2 pins, PrisemiTVS diodeSMB2 pinsPrisemi
- What it is
- TVS diode
- Maker
- Prisemi
- Package
- SMB
- Pins
- 2
- Details
- TVS diode, 160 V working
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
2BZX84C47SOT-23Zener diode, 3 pins, DiotecZener diodeSOT-233 pinsDiotec
- What it is
- Zener diode
- Maker
- Diotec
- Package
- SOT-23
- Pins
- 3
- Details
- SMD Planar Zener Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
824520162SMBTVS diode, 2 pins, Würth ElektronikTVS diodeSMB2 pinsWürth Elektronik
- What it is
- TVS diode
- Maker
- Würth Elektronik
- Package
- SMB
- Pins
- 2
- Details
- WE-TVSP Power TVS Diode SMBJ160A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ASMBJ160A-HFSMBTVS diode, 2 pins, ComchipTVS diodeSMB2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMB
- Pins
- 2
- Details
- 160 V 600 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ASMF160CA-HFSOD-123FTVS diode, 2 pins, ComchipTVS diodeSOD-123F2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SOD-123F
- Pins
- 2
- Details
- 160 V 200 W bidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ATV02W161B-HFSOD-123FTVS diode, 2 pins, ComchipTVS diodeSOD-123F2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SOD-123F
- Pins
- 2
- Details
- 160 V 200 W bidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ATV06B161J-HFSMBTVS diode, 2 pins, ComchipTVS diodeSMB2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMB
- Pins
- 2
- Details
- 160 V 600 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
BZD84C47SOT-23Zener diode, 3 pins, Formosa MicrosemiZener diodeSOT-233 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BZD84C47-Q1SOT-23Zener diode, 3 pins, Formosa MicrosemiZener diodeSOT-233 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CH3906SGPSOT-363Dual PNP transistor, 6 pins, ChenmkoDual PNP transistorSOT-3636 pinsChenmko
- What it is
- Dual PNP transistor
- Maker
- Chenmko
- Package
- SOT-363
- Pins
- 6
- Details
- PNP Switching Transistor, 40 V, 0.2 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor pair.
GSMA6J160ASMATVS diode, 2 pins, Good-ArkTVS diodeSMA2 pinsGood-Ark
- What it is
- TVS diode
- Maker
- Good-Ark
- Package
- SMA
- Pins
- 2
- Details
- TVS diode, 600 W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GSP6SMAFJ160ASMAFTVS diode, 2 pins, Good-ArkTVS diodeSMAF2 pinsGood-Ark
- What it is
- TVS diode
- Maker
- Good-Ark
- Package
- SMAF
- Pins
- 2
- Details
- TVS diode, 600 W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
KRA114SSOT-23Digital transistor (PNP, resistors built in), 3 pins, KECDigital transistor (PNP, resistors built in)SOT-233 pinsKEC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- KEC
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
KRA314SOT-323Digital transistor (PNP, resistors built in), 3 pins, KECDigital transistor (PNP, resistors built in)SOT-3233 pinsKEC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- KEC
- Package
- SOT-323
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
1 more part has no package on record
BAR64-04/WPIN diode, InfineonPIN diodeNot recordedNot recordedInfineon
- What it is
- PIN diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PIN diode or varicap.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PNP transistor pair
Diode range, part lifted. Test each transistor on its own pins, as the datasheet's pinout gives them.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as PPs
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with PPs
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 8 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.
1 identification has been run against this marking.