SMD code RY in SOT-89
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
8 parts in SOT-89 are printed RY
Not sure which one you have?
Answer up to 4 quick questions and these 20 parts are ranked, with a meter test that settles it. It works on a dead part too.
2SA1024-YSOT-89PNP transistor, ToshibaPNP transistorToshiba
- What it is
- PNP transistor
- Maker
- Toshiba
- Package
- SOT-89
- Pins
- 3
- Details
- Si-pnp: GP, 30V, 800mA, 500mW, B=160..320, 120MHz
- Source
- Published code list
Is it dead? The meter test is below: PNP transistor.
2SA1204SOT-89PNP transistor, Galaxy MicroelectronicsPNP transistorGalaxy Microelectronics
- What it is
- PNP transistor
- Maker
- Galaxy Microelectronics
- Package
- SOT-89
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: PNP transistor.
2SA1204-YSOT-89PNP transistor, ToshibaPNP transistorToshiba
- What it is
- PNP transistor
- Maker
- Toshiba
- Package
- SOT-89
- Pins
- 3
- Details
- Si-pnp: GP, 35V, 800mA, 500mW, B=120..240, 120MHz
- Source
- Published code list
Is it dead? The meter test is below: PNP transistor.
2SA1204YSOT-89ToshibaNot recordedToshiba
- What it is
- Not recorded
- Maker
- Toshiba
- Package
- SOT-89
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SA1664SOT-89PNP transistor, Galaxy MicroelectronicsPNP transistorGalaxy Microelectronics
- What it is
- PNP transistor
- Maker
- Galaxy Microelectronics
- Package
- SOT-89
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: PNP transistor.
2SA1664-YSOT-89Transys ElectronicsNot recordedTransys Electronics
- What it is
- Not recorded
- Maker
- Transys Electronics
- Package
- SOT-89
- Pins
- 3
- Details
- Si-pnp: AF, Sw, 35V, 800mA, 500mW, 120MHz, B=160..320
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SJ361SOT-89P-channel MOSFET, RenesasP-channel MOSFETRenesas
- What it is
- P-channel MOSFET
- Maker
- Renesas
- Package
- SOT-89
- Pins
- 3
- Details
- p-MOS*-e: V-MOS, LogL, 20V, 2A, <0,4Ω(1A), integr. Rgate
- Source
- Published code list
Is it dead? The meter test is below: P-channel MOSFET.
KTA1664-YSOT-89PNP transistor, KECPNP transistorKEC
- What it is
- PNP transistor
- Maker
- KEC
- Package
- SOT-89
- Pins
- 3
- Details
- Si-pnp: AF-Drv, 35V, 800mA, 500mW, B=160..320, >120MHz
- Source
- Published code list
Is it dead? The meter test is below: PNP transistor.
7 more parts have no package on record. Nothing rules them out, so they stay.
2SC3898Digital transistor (NPN, resistors built in), Sanyo ElectricDigital transistor (NPN, resistors built in)Sanyo Electric
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- Sanyo Electric
- Package
- Not recorded
- Pins
- Not recorded
- Details
- NPN transistor: Sw, 50V, 100mA, 200mW, 250MHz, B>100, R1=47k
- Source
- Published code list
Is it dead? The meter test is below: Digital transistor.
2SC5541Sanyo ElectricNot recordedSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Si-npn: UHF-S-Band, LN, 9V, 30mA, 100mW, B=90..200, 13GHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
BD53E56G-MVoltage supervisor, ROHMVoltage supervisorROHM
- What it is
- Voltage supervisor
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.6V±1%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127C52FNRVoltage supervisor, IXYSVoltage supervisorIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.2V±0.8%, +Reset PPO, -MR, 50ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
KDZ8.2VVYZener diode, KECZener diodeKEC
- What it is
- Zener diode
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode: 8.02..8.36V, Izt=5mA, Zzt=20, 100mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
XC6127C52FNRVoltage supervisor, TorexVoltage supervisorTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.2V±0.8%, +Reset PPO, -MR, Rdt=50ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6129C52L9R-GVoltage supervisor, TorexVoltage supervisorTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.2V±0.8%, +Reset PPO, Releas. Delay, Det. Delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
PNP transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.