Skip to content

SMD code U02

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

U02 on a chip capacitor

20 nF

20 nF capacitor

The u is both the decimal point and the unit: 20 nF.

Check it with a meter

Lift one end and measure it on a capacitance range. A good one reads close to 20 nF. In circuit the meter also sees everything connected across it, so the reading means little until it is out. A failed one usually reads near 0 Ω, or a steady low resistance, on the ohms range, often from a crack. On the board a shorted capacitor shorts its whole rail. A failed reading does not change what to fit: the marking still says 20 nF.

On a transistor or diode body (SOT-23-5, DFN, Axial), U02 is a part code instead. Those parts are listed below.

2 parts are printed U02

Not sure which one you have?

Answer up to 4 quick questions and these 2 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • EU02AxialRectifier, 2 pins, SankenRectifierAxial2 pinsSanken
    What it is
    Rectifier
    Maker
    Sanken
    Package
    Axial
    Pins
    2
    Details
    Fast Recovery Diode (VRM = 400 V, IF(AV) = 1.0 A, trr = 400 ns)
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Silicon diode.

  • 1 more part has no package on record
    • US5U2N-channel MOSFETN-channel MOSFETNot recordedNot recordedNot recorded
      What it is
      N-channel MOSFET
      Maker
      Not recorded
      Package
      Not recorded
      Pins
      Not recorded
      Details
      N-Channel MOSFET + Schottky Barrier Diode
      Source
      Published code list

      Is it dead? The meter test is below: N-channel MOSFET.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

N-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as U02

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with U02

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.