U041 on a chip capacitor

41 nF

41 nF capacitor

The u is both the decimal point and the unit: 41 nF.

Check it with a meter

Lift one end and measure it on a capacitance range. A good one reads close to 41 nF. In circuit the meter also sees everything connected across it, so the reading means little until it is out. A failed one usually reads near 0 Ω, or a steady low resistance, on the ohms range, often from a crack. On the board a shorted capacitor shorts its whole rail. A failed reading does not change what to fit: the marking still says 41 nF.

On a transistor or diode body (SOT-23-5), U041 is a part code instead. Those parts are listed below.

The only part printed U041 in our tables

TLV9041UIDBV

What it is
Operational amplifier
Maker
Texas Instruments
Package
SOT-23-5
Pins
5
Details
1.2V Ultra Low Voltage, 10µA Micro-Power RRIO Amplifier for Power Conscious Applications
Source
From the manufacturer's datasheet

Is it dead?

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.