SMD code V4 in SOT-23
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
15 parts in SOT-23 are printed V4
Not sure which one you have?
Answer up to 4 quick questions and these 31 parts are ranked, with a meter test that settles it. It works on a dead part too.
all SOT-23, 3 pins. What differs:
BAT54SSOT-23Schottky diode, NexperiaSchottky diodeNexperia
- What it is
- Schottky diode
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Pinout
- 1 anode of diode 1
- 2 cathode of diode 2
- 3 cathode of diode 1 and anode of diode 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
DZ23C3V6SOT-23Zener diode, PanjitZener diodePanjit
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
PESD5V0L2BTSOT-23ESD protection diode, NexperiaESD protection diodeNexperia
- What it is
- ESD protection diode
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- Low capacitance double bidirectional ESD protection diode in SOT23
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
1SV228SOT-23ToshibaNot recordedToshiba
- What it is
- Not recorded
- Maker
- Toshiba
- Package
- SOT-23
- Pins
- 3
- Details
- 2 x FM tuning varicap 30pF
- Source
- Published code list
Is it dead? The meter test is below: PIN diode or varicap.
2SD596-4SOT-23RenesasNot recordedRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: AF, 30V, 700mA, 200mW, B=200..320, 170MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SD596A-4SOT-23RenesasNot recordedRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: AF, 30V, 700mA, 200mW, B=200..320, 170MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SD780-4SOT-23RenesasNot recordedRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: AF, 60V, 300mA, 200mW, B=200..320, 100MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SK303-4SOT-23Sanyo ElectricNot recordedSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- SOT-23
- Pins
- 3
- Details
- n-FET: AF-Amp, 30V, 20mA, 200mW, Idss=2.5..6mA, Ciss=5pF
- Source
- Published code list
Is it dead? The meter test is below: MOSFET.
APX803-44SASOT-23Voltage supervisor, Diodes IncorporatedVoltage supervisorDiodes Incorporated
- What it is
- Voltage supervisor
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 4.38V±1.5%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
APX803S-44SASOT-23Voltage supervisor, Diodes IncorporatedVoltage supervisorDiodes Incorporated
- What it is
- Voltage supervisor
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 4.38V±1.5%, -Reset ODO, Rdt=240ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BFT25RSOT-23Mullard Electronic Products Limited / VALVO GmbHNot recordedMullard Electronic Products Limited / VALVO GmbH
- What it is
- Not recorded
- Maker
- Mullard Electronic Products Limited / VALVO GmbH
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: UHF-A, 8V, 6,5mA, 30mW, B>20, >2,3GHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
DZ23-C3V6SOT-23Diodes IncorporatedNot recordedDiodes Incorporated
- What it is
- Not recorded
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- Z-diode: Dual, 3.6V±5%, 300mW
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
DZ23C3V6-VSOT-23Zener diode, VishayZener diodeVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 3.6V Dual Zener Diodes
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
ELM7624LBBSOT-23Voltage supervisor, ELM TechnologyVoltage supervisorELM Technology
- What it is
- Voltage supervisor
- Maker
- ELM Technology
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.4V±2%, -Reset PPO, Rdt=500ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
SP809NEK-2-3SOT-23Voltage supervisor, SipexVoltage supervisorSipex
- What it is
- Voltage supervisor
- Maker
- Sipex
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.3V±1.5%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with V4
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 17 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.