SMD code X7 in SOT-23
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
8 parts in SOT-23 are printed X7
Not sure which one you have?
Answer up to 4 quick questions and these 23 parts are ranked, with a meter test that settles it. It works on a dead part too.
AO3407ASOT-23P-channel MOSFET, 3 pins, Alpha & Omega SemiconductorP-channel MOSFET3 pinsAlpha & Omega Semiconductor
- What it is
- P-channel MOSFET
- Maker
- Alpha & Omega Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- P-channel MOSFET (8-60 V)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
AO3407ALSOT-23P-channel MOSFET, 3 pins, Alpha & Omega SemiconductorP-channel MOSFET3 pinsAlpha & Omega Semiconductor
- What it is
- P-channel MOSFET
- Maker
- Alpha & Omega Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- P-channel MOSFET (8-60 V)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
2SD1048-7SOT-233 pins, Sanyo ElectricNot recorded3 pinsSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: AF-Amp, 20V, 700mA, 200mW, B=300..400, 250MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
APX809-26SASOT-23Voltage supervisor, 3 pins, Diodes IncorporatedVoltage supervisor3 pinsDiodes Incorporated
- What it is
- Voltage supervisor
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.63V±1.5%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
APX809S-26SA-7SOT-23Voltage supervisor, 3 pins, Diodes IncorporatedVoltage supervisor3 pinsDiodes Incorporated
- What it is
- Voltage supervisor
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.63V±1.5%, -Reset PPO, Rdt=240ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BZX84-C47SOT-23Zener diode, 3 pins, Diodes IncorporatedZener diode3 pinsDiodes Incorporated
- What it is
- Zener diode
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- 47 V approx. ±5% voltage regulator (Zener) diode
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
BZX84C47SOT-23Zener diode, 3 pins, Siemens / Zetex plcZener diode3 pinsSiemens / Zetex plc
- What it is
- Zener diode
- Maker
- Siemens / Zetex plc
- Package
- SOT-23
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
BZX88-C47SOT-233 pins, Ferranti SemiconductorsNot recorded3 pinsFerranti Semiconductors
- What it is
- Not recorded
- Maker
- Ferranti Semiconductors
- Package
- SOT-23
- Pins
- 3
- Details
- Z-diode: 47V±5%, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
7 more parts have no package on record. Nothing rules them out, so they stay.
LD39030DTPU18RLDO regulator, STMicroelectronicsLDO regulatorNot recordedSTMicroelectronics
- What it is
- LDO regulator
- Maker
- STMicroelectronics
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
NX3P1107UKLoad switch, NXPLoad switchNot recordedNXP
- What it is
- Load switch
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Logic controlled high-side power switch
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Load switch.
ZGFM105V6B-MSZener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
ZGFM105V6B-MS-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
ZGFM105V6B-MSTZener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
ZGFM105V6B-MST-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
74LVC2G34FX4Diodes IncorporatedNot recordedNot recordedDiodes Incorporated
- What it is
- Not recorded
- Maker
- Diodes Incorporated
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Dual noniverting buffers
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Load switch
Voltage, board powered, black probe on ground.
Working, it reads
Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.
Dead, it reads
- Output at the input voltage while switched off: the pass element has shorted.
- Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
- On the board:
- An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as X7
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with X7
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 1 more part.
Did you find your part?
Open this in the search to correct a character or try another package.