54 parts are printed -5Z
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
MM1Z39BWSOD-123Zener diode, 2 pins, JSMSEMIZener diodeSOD-1232 pinsJSMSEMI
- What it is
- Zener diode
- Maker
- JSMSEMI
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM1Z39WSOD-123Zener diode, 2 pins, HXYZener diodeSOD-1232 pinsHXY
- What it is
- Zener diode
- Maker
- HXY
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode, 22 V, 0.005 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM3Z3V9BSOD-323Zener diode, 2 pins, onsemiZener diodeSOD-3232 pinsonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM5Z47V-CSOD-523Zener diode, 2 pins, SeCoSZener diodeSOD-5232 pinsSeCoS
- What it is
- Zener diode
- Maker
- SeCoS
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MT5Z47V-CSOD-523Zener diode, 2 pins, SeCoSZener diodeSOD-5232 pinsSeCoS
- What it is
- Zener diode
- Maker
- SeCoS
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
TBZT52B3V9SSOD-323Zener diode, 2 pins, Galaxy MicroelectronicsZener diodeSOD-3232 pinsGalaxy Microelectronics
- What it is
- Zener diode
- Maker
- Galaxy Microelectronics
- Package
- SOD-323
- Pins
- 2
- Details
- 3.9V, 200mW, Surface Mount Zener Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
2SK4029SOT-323N-channel MOSFET, 3 pins, PanasonicN-channel MOSFETSOT-3233 pinsPanasonic
- What it is
- N-channel MOSFET
- Maker
- Panasonic
- Package
- SOT-323
- Pins
- 3
- Details
- MOSFET n-type: Sw, 25V, 1A, 500mW, 0.26 (500mA), 8/30ns
- Source
- Published code list
Is it dead? The meter test is below: N-channel MOSFET.
BZT52-B3V9SSOD-323Zener diode, 2 pins, Taiwan SemiconductorZener diodeSOD-3232 pinsTaiwan Semiconductor
- What it is
- Zener diode
- Maker
- Taiwan Semiconductor
- Package
- SOD-323
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
HFA3135IHZ96SOT-23-66 pins, RenesasNot recordedSOT-23-66 pinsRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-23-6
- Pins
- 6
- Source
- Published code list
Is it dead? The meter test is below: This part.
6 more parts have no package on record
MM3Z3V9BW-CZener diode, SeCoSZener diodeNot recordedNot recordedSeCoS
- What it is
- Zener diode
- Maker
- SeCoS
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
SGM458HTGTemperature sensor, 4 pins, SG MicroTemperature sensorNot recorded4 pinsSG Micro
- What it is
- Temperature sensor
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 4
- Details
- Low Power, Low Supply Voltage, CSP Package, Digital Temperature Sensor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
SGM41107-62PF61YXDH4GBattery protection IC, 4 pins, SG MicroBattery protection ICNot recorded4 pinsSG Micro
- What it is
- Battery protection IC
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 4
- Details
- True Monolithic Li-Ion/Polymer Battery Protector in Tiny Thin Package
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
IXD5126C55A7R-GVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.5V±0.8%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127C53ANRVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.3V±0.8%, -Reset PPO, -MR, 50ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127N53FNRVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.3V±0.8%, +Reset ODO, -MR, 50ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.