91 parts are printed -6D

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • GBLC15CDSLASOD-323ESD protection diode, 2 pins, ProTek DevicesESD protection diodeSOD-3232 pinsProTek Devices
    What it is
    ESD protection diode
    Maker
    ProTek Devices
    Package
    SOD-323
    Pins
    2
    Details
    Ultra Low Capacitance TVS Array
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • KIA7025AFSOT-89Voltage supervisor, 3 pins, KECVoltage supervisorSOT-893 pinsKEC
    What it is
    Voltage supervisor
    Maker
    KEC
    Package
    SOT-89
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • LDTA114YM3T5GSOT-723Digital transistor (PNP, resistors built in), 3 pins, LRCDigital transistor (PNP, resistors built in)SOT-7233 pinsLRC
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    LRC
    Package
    SOT-723
    Pins
    3
    Details
    Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • LMUN5114T1GSOT-323Digital transistor (PNP, resistors built in), 3 pins, LRCDigital transistor (PNP, resistors built in)SOT-3233 pinsLRC
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    LRC
    Package
    SOT-323
    Pins
    3
    Details
    Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • MM1Z 56SOD-123Zener diode, 2 pins, HottechZener diodeSOD-1232 pinsHottech
    What it is
    Zener diode
    Maker
    Hottech
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode, VZ 56 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MM1Z 56LSOD-123FZener diode, 2 pins, HottechZener diodeSOD-123F2 pinsHottech
    What it is
    Zener diode
    Maker
    Hottech
    Package
    SOD-123F
    Pins
    2
    Details
    Zener diode, VZ 56 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MM1Z56SOD-123Zener diode, 2 pins, HXYZener diodeSOD-1232 pinsHXY
    What it is
    Zener diode
    Maker
    HXY
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode, 27 V, 0.005 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MM1Z56BWSOD-123Zener diode, 2 pins, JSMSEMIZener diodeSOD-1232 pinsJSMSEMI
    What it is
    Zener diode
    Maker
    JSMSEMI
    Package
    SOD-123
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MM1Z56WSOD-123Zener diode, 2 pins, HXYZener diodeSOD-1232 pinsHXY
    What it is
    Zener diode
    Maker
    HXY
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode, 22 V, 0.005 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MMBF5457SOT-23N-channel MOSFET, 3 pins, onsemiN-channel MOSFETSOT-233 pinsonsemi
    What it is
    N-channel MOSFET
    Maker
    onsemi
    Package
    SOT-23
    Pins
    3
    Details
    N-Channel General Purpose Amplifier
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: N-channel MOSFET.

  • MUN2114SOT-23Digital transistor (PNP, resistors built in), 3 pins, onsemiDigital transistor (PNP, resistors built in)SOT-233 pinsonsemi
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    onsemi
    Package
    SOT-23
    Pins
    3
    Details
    Digital Transistors (BRT) R1 = 10 k  , R2 = 47 k 
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • 4 more parts have no package on record
    • FSA4480UCXAnalog switch, onsemiAnalog switchNot recordedNot recordedonsemi
      What it is
      Analog switch
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      USB Type-C  Analog Audio Switch with Protection Function
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • KIA7025ATVoltage supervisor, KECVoltage supervisorNot recordedNot recordedKEC
      What it is
      Voltage supervisor
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • LDTA114YET1GDigital transistor (PNP, resistors built in), LRCDigital transistor (PNP, resistors built in)Not recordedNot recordedLRC
      What it is
      Digital transistor (PNP, resistors built in)
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Digital transistor.

    • LN2406DT2AGN-channel MOSFET, LRCN-channel MOSFETNot recordedNot recordedLRC
      What it is
      N-channel MOSFET
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MOSFET, N-Channel, VDSS 60 V, VGS 12 V
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: N-channel MOSFET.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

N-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.