SMD code -P4
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
101 parts are printed -P4
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
BZX84-C15TSOT-5233 pins, Diodes IncorporatedNot recordedSOT-5233 pinsDiodes Incorporated
- What it is
- Not recorded
- Maker
- Diodes Incorporated
- Package
- SOT-523
- Pins
- 3
- Details
- Z-diode: 15V±5%, 150mW
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
BZX84-C15TSSOT-3636 pins, Diodes IncorporatedNot recordedSOT-3636 pinsDiodes Incorporated
- What it is
- Not recorded
- Maker
- Diodes Incorporated
- Package
- SOT-363
- Pins
- 6
- Details
- Z-diode: Triple, 3x15V±5%, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
BZX84C15TSOT-523Zener diode, 3 pins, Diodes IncorporatedZener diodeSOT-5233 pinsDiodes Incorporated
- What it is
- Zener diode
- Maker
- Diodes Incorporated
- Package
- SOT-523
- Pins
- 3
- Details
- zener 150mW 15V
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
CMOZ22LSOD-523Zener diode, 2 pins, Central SemiconductorZener diodeSOD-5232 pinsCentral Semiconductor
- What it is
- Zener diode
- Maker
- Central Semiconductor
- Package
- SOD-523
- Pins
- 2
- Details
- Z-diode: 20.90..23.10V, Izt=0.25mA, Zzt=150Ω, 250mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
CZRH3-55C15SOT-523Zener diode, 3 pins, ComchipZener diodeSOT-5233 pinsComchip
- What it is
- Zener diode
- Maker
- Comchip
- Package
- SOT-523
- Pins
- 3
- Details
- Zener diode: 15.0..15.60V, Zzt=30, Izt=5mA, 150mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
ELM7334CBC2ASOT-353Voltage supervisor, 5 pins, ELM TechnologyVoltage supervisorSOT-3535 pinsELM Technology
- What it is
- Voltage supervisor
- Maker
- ELM Technology
- Package
- SOT-353
- Pins
- 5
- Details
- Voltage detector IC: 3.4V±1.2%, -Reset PPO, -MR
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
ELM7624HCBSOT-23Voltage supervisor, 3 pins, ELM TechnologyVoltage supervisorSOT-233 pinsELM Technology
- What it is
- Voltage supervisor
- Maker
- ELM Technology
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.4V±2%, +Reset PPO, Rdt=150ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
ELM9724CABSOT-89Voltage supervisor, 3 pins, ELM TechnologyVoltage supervisorSOT-893 pinsELM Technology
- What it is
- Voltage supervisor
- Maker
- ELM Technology
- Package
- SOT-89
- Pins
- 3
- Details
- Voltage detector IC: 2.4V±2.5%, +Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
ELM9724CBBSOT-23Voltage supervisor, 3 pins, ELM TechnologyVoltage supervisorSOT-233 pinsELM Technology
- What it is
- Voltage supervisor
- Maker
- ELM Technology
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.4V±2.5%, +Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
ILC5061IC44XSOT-3233 pins, IMPNot recordedSOT-3233 pinsIMP
- What it is
- Not recorded
- Maker
- IMP
- Package
- SOT-323
- Pins
- 3
- Details
- CMOS-IC: Voltage Detector 4.4V±2%, -Reset Open-Drain Output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
ILC5061M44XSOT-233 pins, IMPNot recordedSOT-233 pinsIMP
- What it is
- Not recorded
- Maker
- IMP
- Package
- SOT-23
- Pins
- 3
- Details
- CMOS-IC: Voltage Detector 4.4V±2%, -Reset Open-Drain Output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
4 more parts have no package on record
DW84C15NND03Zener diode, JSCJZener diodeNot recordedNot recordedJSCJ
- What it is
- Zener diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode: 15V±10%, If=10mA, 150mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
ELM9724CAAVoltage supervisor, ELMVoltage supervisorNot recordedNot recordedELM
- What it is
- Voltage supervisor
- Maker
- ELM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
FSA266L8XFairchild SemiconductorNot recordedNot recordedNot recordedFairchild Semiconductor
- What it is
- Not recorded
- Maker
- Fairchild Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-channel analog switch
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
HVC134HitachiNot recordedNot recordedNot recordedHitachi
- What it is
- Not recorded
- Maker
- Hitachi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- PIN-diode: HF-Sw, 65V, 100mA, 0,4pF, <2Ω(10mA/100MHz)
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.