Skip to content

SMD code -P5

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

104 parts are printed -P5

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • S-LMUN5113T1GSOT-323Digital transistor (PNP, resistors built in), 3 pins, LRCDigital transistor (PNP, resistors built in)SOT-3233 pinsLRC
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    LRC
    Package
    SOT-323
    Pins
    3
    Details
    Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • SBZX584B22V-CSOD-523Zener diode, 2 pins, SeCoSZener diodeSOD-5232 pinsSeCoS
    What it is
    Zener diode
    Maker
    SeCoS
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • TBZT52B22LSOD-882Zener diode, 2 pins, Galaxy MicroelectronicsZener diodeSOD-8822 pinsGalaxy Microelectronics
    What it is
    Zener diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-882
    Pins
    2
    Details
    22V, 100mW, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • TGESD0502BSOT-523ESD protection diode, 3 pins, Galaxy MicroelectronicsESD protection diodeSOT-5233 pinsGalaxy Microelectronics
    What it is
    ESD protection diode
    Maker
    Galaxy Microelectronics
    Package
    SOT-523
    Pins
    3
    Details
    5V, 125W, Surface Mount TVS
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • WE05DFSOD-882ESD protection diode, 2 pins, WayonESD protection diodeSOD-8822 pinsWayon
    What it is
    ESD protection diode
    Maker
    Wayon
    Package
    SOD-882
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • ZD5270BSHSOD-123Zener diode, 2 pins, CYStekZener diodeSOD-1232 pinsCYStek
    What it is
    Zener diode
    Maker
    CYStek
    Package
    SOD-123
    Pins
    2
    Details
    91 V zener diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 2SD1161-P5SOT-233 pins, Sanyo ElectricNot recordedSOT-233 pinsSanyo Electric
    What it is
    Not recorded
    Maker
    Sanyo Electric
    Package
    SOT-23
    Pins
    3
    Details
    Si-npn: GP, 30V, 0,03A, Emitter-R=130Ω,
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 74AUP1T45GWSOT-3636 pins, NXPNot recordedSOT-3636 pinsNXP
    What it is
    Not recorded
    Maker
    NXP
    Package
    SOT-363
    Pins
    6
    Details
    CMOS logic IC: Dual supply translating transceiver with 3-state output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BB135SOD-3232 pins, PhiNot recordedSOD-3232 pinsPhi
    What it is
    Not recorded
    Maker
    Phi
    Package
    SOD-323
    Pins
    2
    Details
    UHF Varicap 2-12pF
    Source
    Published code list

    Is it dead? The meter test is below: PIN diode or varicap.

  • 6 more parts have no package on record
    • PU1BMRectifier, Taiwan SemiconductorRectifierNot recordedNot recordedTaiwan Semiconductor
      What it is
      Rectifier
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Silicon diode.

    • 74AUP1T45GFNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual supply translating transceiver with 3-state output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP1T45GMNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual supply translating transceiver with 3-state output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP1T45GNNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual supply translating transceiver with 3-state output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 74AUP1T45GSNXPNot recordedNot recordedNot recordedNXP
      What it is
      Not recorded
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: Dual supply translating transceiver with 3-state output
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • BD46E461G-MVoltage supervisor, ROHMVoltage supervisorNot recordedNot recordedROHM
      What it is
      Voltage supervisor
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 4.6V±1%, -MR, -Reset PPO, Rdt=100ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.