Skip to content

SMD code 03

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ESD0603B3V3ADFN0603-2ESD protection diode, 2 pins, YFWESD protection diodeDFN0603-22 pinsYFW
    What it is
    ESD protection diode
    Maker
    YFW
    Package
    DFN0603-2
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • FDG6303NSOT-363Dual N-channel MOSFET, 6 pins, onsemiDual N-channel MOSFETSOT-3636 pinsonsemi
    What it is
    Dual N-channel MOSFET
    Maker
    onsemi
    Package
    SOT-363
    Pins
    6
    Details
    Digital FET, Dual N-Channel
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: N-channel MOSFET pair.

  • GALI-3+SOT-89RF amplifier (MMIC), 3 pins, Mini-CircuitsRF amplifier (MMIC)SOT-893 pinsMini-Circuits
    What it is
    RF amplifier (MMIC)
    Maker
    Mini-Circuits
    Package
    SOT-89
    Pins
    3
    Details
    MMIC amplifier, DC-3 GHz
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: RF amplifier.

  • GSOT03SOT-23ESD protection diode, 3 pins, Galaxy MicroelectronicsESD protection diodeSOT-233 pinsGalaxy Microelectronics
    What it is
    ESD protection diode
    Maker
    Galaxy Microelectronics
    Package
    SOT-23
    Pins
    3
    Details
    3.3V, 369W, Surface Mount TVS
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • GSOT03-E3-08SOT-23TVS diode, 3 pins, UMWTVS diodeSOT-233 pinsUMW
    What it is
    TVS diode
    Maker
    UMW
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • JEU03D3SOD-323TVS diode, 2 pins, JieJieTVS diodeSOD-3232 pinsJieJie
    What it is
    TVS diode
    Maker
    JieJie
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • JEU03D3-AUSOD-323TVS diode, 2 pins, JieJieTVS diodeSOD-3232 pinsJieJie
    What it is
    TVS diode
    Maker
    JieJie
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • PDTA114ETSOT-23Digital transistor (PNP, resistors built in), 3 pins, NexperiaDigital transistor (PNP, resistors built in)SOT-233 pinsNexperia
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Pinout
    • 1 base
    • 2 emitter
    • 3 collector
    Details
    50 V, 100 mA PNP resistor-equipped transistor; R1 = 10 kOhm, R2 = 10 kOhm
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • PDTA114EUSOT-323Digital transistor (PNP, resistors built in), 3 pins, NexperiaDigital transistor (PNP, resistors built in)SOT-3233 pinsNexperia
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    Nexperia
    Package
    SOT-323
    Pins
    3
    Details
    50 V, 100 mA PNP resistor-equipped transistor; R1 = 10 kΩ, R2 = 10 kΩ
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • PSOT03SOT-23ESD protection diode, 3 pins, ProTek DevicesESD protection diodeSOT-233 pinsProTek Devices
    What it is
    ESD protection diode
    Maker
    ProTek Devices
    Package
    SOT-23
    Pins
    3
    Details
    500W TVS Array
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • PSOT03-LF-T7SOT-233 pins, UMWNot recordedSOT-233 pinsUMW
    What it is
    Not recorded
    Maker
    UMW
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: This part.

  • PTVSLC3D3V3USOD-323ESD protection diode, 2 pins, PrisemiESD protection diodeSOD-3232 pinsPrisemi
    What it is
    ESD protection diode
    Maker
    Prisemi
    Package
    SOD-323
    Pins
    2
    Details
    ESD protection diode, 3.3 V working
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 3 more parts have no package on record
    • MAR-3+RF amplifier (MMIC), Mini-CircuitsRF amplifier (MMIC)Not recordedNot recordedMini-Circuits
      What it is
      RF amplifier (MMIC)
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MMIC amplifier, DC-2 GHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: RF amplifier.

    • MAR-3SM+RF amplifier (MMIC), Mini-CircuitsRF amplifier (MMIC)Not recordedNot recordedMini-Circuits
      What it is
      RF amplifier (MMIC)
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MMIC amplifier, DC-2 GHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: RF amplifier.

    • RBR3L60ASchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
      What it is
      Schottky diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

N-channel MOSFET pair

Diode range, part lifted. Test drain to source first, then short gate to source and test again. Test each MOSFET on its own pins, as the datasheet's pinout gives them.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

RF amplifier

Voltage, board powered, on the output pin that the bias resistor or choke feeds.

Working, it reads

The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

Dead, it reads

  • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
  • Output pin at the full supply voltage: open inside, no current flowing.
On the board:
Measured on the board with power on; the bias network is part of the reading.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The figures depend on the part and its bias resistor. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.