SMD code 06A
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
06A on a chip resistor
113 Ω
113 Ω resistor, 1%
EIA-96 precision code: 06 stands for 113 in the E96 table, and the letter A is the multiplier, × 1. These are 1% parts.
Check it with a meter
Lift one end and measure across it. A good one reads 113 Ω within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 113 Ω on the board is a fault. Open, or well above 113 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 113 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.
On a transistor or diode body (SOT-23-5, MSOP-10, SMB), 06A is a part code instead. Those parts are listed below.
3 parts are printed 06A
Not sure which one you have?
Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.
P0640SAASMA2 pins, VishayNot recordedSMA2 pinsVishay
- What it is
- Not recorded
- Maker
- Vishay
- Package
- SMA
- Pins
- 2
- Details
- Thyristor surge protector: Vdrm=58V, Vs=77V, Ipp=35A(1ms), Bidir.
- Source
- Published code list
Is it dead? The meter test is below: This part.
XC6101B241MRSOT-23-5Voltage supervisor, 5 pins, TorexVoltage supervisorSOT-23-55 pinsTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-23-5
- Pins
- 5
- Details
- CMOS-IC: VDet 4.1V, 5%, Hst, -MR, -Reset PPO, Wt=50ms, Rt=25ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
1 more part has no package on record
UMA6.0ATVS diode, Microsemi Integrated Products DivisionTVS diodeNot recordedNot recordedMicrosemi Integrated Products Division
- What it is
- TVS diode
- Maker
- Microsemi Integrated Products Division
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vrwm=6.0V, Vbr=6.67..10.3V, 48.5A, 500W(1ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 06A
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with 06A
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 1 more part.
Did you find your part?
Open this in the search to correct a character or try another package.