Skip to content

SMD code 10- in SOT-23

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

13 parts in SOT-23 are printed 10-

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • CHM2310GPSOT-23N-channel MOSFET, ChenmkoN-channel MOSFETChenmko
    What it is
    N-channel MOSFET
    Maker
    Chenmko
    Package
    SOT-23
    Pins
    3
    Details
    N-Channel Enhancement Mode Field Effect Transistor, 30 V, 4.8 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: N-channel MOSFET.

  • CHM2310GP-ASOT-23N-channel MOSFET, ChenmkoN-channel MOSFETChenmko
    What it is
    N-channel MOSFET
    Maker
    Chenmko
    Package
    SOT-23
    Pins
    3
    Details
    N-Channel Enhancement Mode Field Effect Transistor, 30 V, 4.8 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: N-channel MOSFET.

  • EMF20N02JSOT-23N-channel MOSFET, Excelliance MOSN-channel MOSFETExcelliance MOS
    What it is
    N-channel MOSFET
    Maker
    Excelliance MOS
    Package
    SOT-23
    Pins
    3
    Details
    20 V, 6 A N-channel MOSFET
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: N-channel MOSFET.

  • TZT10WSOT-23Zener diode, Taitron ComponentsZener diodeTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOT-23
    Pins
    3
    Details
    SMD Zener Diodes (Three Terminals) - 200mW
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • EMF20N02JSSOT-23N-channel MOSFET, Excelliance MOSN-channel MOSFETExcelliance MOS
    What it is
    N-channel MOSFET
    Maker
    Excelliance MOS
    Package
    SOT-23
    Pins
    3
    Details
    20 V, 6 A N-channel MOSFET
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: N-channel MOSFET.

  • 1PS59SB10SOT-23NexperiaNot recordedNexperia
    What it is
    Not recorded
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Details
    30V 0.2A schottky diode
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • AP8822C-50GASOT-23Voltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 5.0V±2%, -Reset PPO, Rdt=200ms, H-free
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AP8822C-50PASOT-23Voltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 5.0V±2%, -Reset PPO, Rdt=200ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BAT18SOT-23NexperiaNot recordedNexperia
    What it is
    Not recorded
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Details
    equivalent BA482
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • EC95810C50B1NSOT-23Voltage supervisor, E-CMOSVoltage supervisorE-CMOS
    What it is
    Voltage supervisor
    Maker
    E-CMOS
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 5.0V±2%, -Reset PPO, Rdt=200ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • SSTPAD10SOT-23SiliconixNot recordedSiliconix
    What it is
    Not recorded
    Maker
    Siliconix
    Package
    SOT-23
    Pins
    3
    Details
    equivalent JPAD10
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • Z02W10VSOT-23Zener diode, KECZener diodeKEC
    What it is
    Zener diode
    Maker
    KEC
    Package
    SOT-23
    Pins
    3
    Source
    An older or alternative marking, from a published code list

    Is it dead? The meter test is below: Zener diode.

  • ZD10-AE3SOT-23Zener diode, UTCZener diodeUTC
    What it is
    Zener diode
    Maker
    UTC
    Package
    SOT-23
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • 2 more parts have no package on record. Nothing rules them out, so they stay.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

N-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 10-

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 12 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.