SMD code 1006
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
1006 on a chip resistor
100 MΩ
100 MΩ resistor, 1%
100 followed by 6 zeros. Four digits is normally the 1% series.
Check it with a meter
Lift one end and measure across it. A good one reads 100 MΩ within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 100 MΩ on the board is a fault. Open, or well above 100 MΩ, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 100 MΩ. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.
On a transistor or diode body (SMB, SOT-23, SOT-23-5), 1006 is a part code instead. Those parts are listed below.
2 parts are printed 1006
Not sure which one you have?
Answer up to 4 quick questions and these 2 parts are ranked, with a meter test that settles it. It works on a dead part too.
GRS1006FHSOD-123FRectifier, 2 pins, Good-ArkRectifierSOD-123F2 pinsGood-Ark
- What it is
- Rectifier
- Maker
- Good-Ark
- Package
- SOD-123F
- Pins
- 2
- Details
- Rectifier, 600 V, 1 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
LT1006S8SOIC-88 pins, Analog DevicesNot recordedSOIC-88 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOIC-8
- Pins
- 8
- Details
- equivalent LT1006CN8
- Source
- Published code list
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 1006
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with 1006
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 20 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.