SMD code 110
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
110 on a chip resistor
11 Ω
11 Ω resistor, 5%
11 followed by 0 zeros. Three digits is normally the 5% series. The same marking also reads as 11 pF on a capacitor or 11 µH on an inductor, and nothing in the code says which; the body of the part does.
Other readings of the same characters, most likely first
- 11 pF capacitor
- 11 µH inductor
Check it with a meter
Lift one end and measure across it. A good one reads 11 Ω within 5%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 11 Ω on the board is a fault. Open, or well above 11 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 11 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.
On a transistor or diode body (SOT-23-5, SOT-23, SMA), 110 is a part code instead. Those parts are listed below.
47 parts are printed 110
Not sure which one you have?
Answer up to 4 quick questions and these 47 parts are ranked, with a meter test that settles it. It works on a dead part too.
1.5SMC110SMCTVS diode, 2 pins, HottechTVS diodeSMC2 pinsHottech
- What it is
- TVS diode
- Maker
- Hottech
- Package
- SMC
- Pins
- 2
- Details
- TVS diode, VRWM 89.2 V, unidirectional
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
3.0SMC110SMCTVS diode, 2 pins, YFWTVS diodeSMC2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMC
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
KIC7110MSOT-23Voltage supervisor, 3 pins, KECVoltage supervisorSOT-233 pinsKEC
- What it is
- Voltage supervisor
- Maker
- KEC
- Package
- SOT-23
- Pins
- 3
- Details
- CMOS voltage detector, 1.0 V detection
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
LMBR1100FT1GSOD-123FSchottky diode, 2 pins, LRCSchottky diodeSOD-123F2 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-123F
- Pins
- 2
- Details
- Schottky diode, VR 100 V, IF 1 A, VF Max 0.85 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
MBR1100SOD-123Schottky diode, 2 pins, Galaxy MicroelectronicsSchottky diodeSOD-1232 pinsGalaxy Microelectronics
- What it is
- Schottky diode
- Maker
- Galaxy Microelectronics
- Package
- SOD-123
- Pins
- 2
- Details
- 1A, 100V, Surface Mount Small Signal Schottky Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
MBR1100SSOD-323Schottky diode, 2 pins, Galaxy MicroelectronicsSchottky diodeSOD-3232 pinsGalaxy Microelectronics
- What it is
- Schottky diode
- Maker
- Galaxy Microelectronics
- Package
- SOD-323
- Pins
- 2
- Details
- 1A, 100V, Surface Mount Small Signal Schottky Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
P6SMBF110SMBFTVS diode, 2 pins, YFWTVS diodeSMBF2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMBF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
S-LMBR1100FT1GSOD-123FSchottky diode, 2 pins, LRCSchottky diodeSOD-123F2 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-123F
- Pins
- 2
- Details
- Schottky diode, VR 100 V, IF 1 A, VF Max 0.85 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
S-LMBR1100FT1G-SSOD-123FSchottky diode, 2 pins, LRCSchottky diodeSOD-123F2 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-123F
- Pins
- 2
- Details
- Schottky diode, VR 100 V, IF 1 A, VF Max 0.85 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
6 more parts have no package on record
ASS110HS-HFSchottky diode, ComchipSchottky diodeNot recordedNot recordedComchip
- What it is
- Schottky diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 100 V, 1 A Schottky barrier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
CHSDAJAGP-ASchottky diode, ChenmkoSchottky diodeNot recordedNot recordedChenmko
- What it is
- Schottky diode
- Maker
- Chenmko
- Package
- Not recorded
- Pins
- Not recorded
- Details
- SCHOTTKY BARRIER RECTIFIER, 100 V, 1.0 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
KIC7110T5Voltage supervisor, KECVoltage supervisorNot recordedNot recordedKEC
- What it is
- Voltage supervisor
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS voltage detector, 1.0 V detection
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
LMBR1100ET1GSchottky diode, LRCSchottky diodeNot recordedNot recordedLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky diode, VR 100 V, IF 1 A, VF Max 0.85 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
MMBFJ110JFET, onsemiJFETNot recordedNot recordedonsemi
- What it is
- JFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- N-Channel JFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: JFET.
S-LMBR1100ET1GSchottky diode, LRCSchottky diodeNot recordedNot recordedLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky diode, VR 100 V, IF 1 A, VF Max 0.85 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
JFET
Ohms range for drain to source, diode range for the gate, part lifted.
Working, it reads
Drain to source conducts both ways at a few hundred ohms, depending on the part, and some meters beep on it. The gate reads one junction to drain and to source, about 0.6 to 0.7 V, and open the other way.
Dead, it reads
- The gate the same both ways to drain or source, near 0 V with a continuous beep: gate shorted.
- Drain to source open: the channel has failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- Drain to source resistance varies from part to part. An identical part elsewhere on the board shows what is normal.
- Watch for:
- A good channel can beep like a short between drain and source. That is normal; the gate junction says whether it has failed.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 110
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 112 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.