  • 3.0SMC120SMCTVS diode, YFWTVS diodeYFW
    What it is
    TVS diode
    Maker
    YFW
    Package
    SMC
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • ACDBMT1200-HFSchottky diode, ComchipSchottky diodeComchip
      What it is
      Schottky diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      200 V, 1 A Schottky barrier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • CDBMT1200-HFSchottky diode, ComchipSchottky diodeComchip
      What it is
      Schottky diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      200 V, 1 A Schottky barrier diode
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM1200-MHSchottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM1200-MH-Q1Schottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM1200-MHTSchottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM1200-MHT-Q1Schottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM1200-MSSchottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM1200-MS-Q1Schottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM1200-MSTSchottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM1200-MST-Q1Schottky diode, Formosa MicrosemiSchottky diodeFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • KIC7120T5Voltage supervisor, KECVoltage supervisorKEC
      What it is
      Voltage supervisor
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS voltage detector, 2.0 V detection
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • LMBR1200ET1GSchottky diode, LRCSchottky diodeLRC
      What it is
      Schottky diode
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky diode, VR 200 V, IF 1 A, VF Max 0.92 V
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • STPS120MSchottky diode, STMicroelectronicsSchottky diodeSTMicroelectronics
      What it is
      Schottky diode
      Maker
      STMicroelectronics
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • 1PMT4120Zener diode, Microsemi Integrated Products DivisionZener diodeMicrosemi Integrated Products Division
      What it is
      Zener diode
      Maker
      Microsemi Integrated Products Division
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 30V±5%, Izt=28.4mA, 1W
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 120

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with 120

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 29 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.