Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

3 parts are printed 123

Not sure which one you have?

Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.

Digital transistor (NPN, resistors built in), all SOT-323, 3 pins, all ROHM.

  • DTC143ZU3SOT-323
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    ROHM
    Package
    SOT-323
    Pins
    3
    Details
    NPN 50V, 100mA digital transistor (bias resistor built-in)
    Source
    From the manufacturer's datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • DTC143ZUASOT-323
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    ROHM
    Package
    SOT-323
    Pins
    3
    Details
    Digital transistor (bias resistors built in), NPN
    Source
    From the manufacturer's datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • DTC143ZUBSOT-323
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    ROHM
    Package
    SOT-323
    Pins
    3
    Details
    NPN digital transistor (bias resistor built-in); R1 = 4.7kOhm, R2 = 47kOhm
    Source
    From the manufacturer's datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

6 more parts have codes that begin with 123

Codes that begin with 123

For a marking with its end worn or burnt off. Each one shows its full printed code.

Zener diode, all Panjit.

  • PZ1AFC3V6Bprinted 1Z3V6B

    Printed 1Z3V6B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    Not recorded
    Pins
    Not recorded
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PZ1AFC3V9Bprinted 1Z3V9B

    Printed 1Z3V9B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    Not recorded
    Pins
    Not recorded
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PZ1AFC30Bprinted 1Z30B

    Printed 1Z30B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    Not recorded
    Pins
    Not recorded
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PZ1AFC33Bprinted 1Z33B

    Printed 1Z33B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    Not recorded
    Pins
    Not recorded
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PZ1AFC36Bprinted 1Z36B

    Printed 1Z36B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    Not recorded
    Pins
    Not recorded
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PZ1AFC39Bprinted 1Z39B

    Printed 1Z39B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    Not recorded
    Pins
    Not recorded
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.