  • FM140-NSOD-323Schottky diode, 2 pins, Formosa MicrosemiSchottky diodeSOD-3232 pinsFormosa Microsemi
    What it is
    Schottky diode
    Maker
    Formosa Microsemi
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • FM140-N-Q1SOD-323Schottky diode, 2 pins, Formosa MicrosemiSchottky diodeSOD-3232 pinsFormosa Microsemi
    What it is
    Schottky diode
    Maker
    Formosa Microsemi
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • FMUN5314DW1SOT-363Digital transistor (resistors built in), 6 pins, Formosa MicrosemiDigital transistor (resistors built in)SOT-3636 pinsFormosa Microsemi
    What it is
    Digital transistor (resistors built in)
    Maker
    Formosa Microsemi
    Package
    SOT-363
    Pins
    6
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • FS14SOD-123FSchottky diode, 2 pins, Good-ArkSchottky diodeSOD-123F2 pinsGood-Ark
    What it is
    Schottky diode
    Maker
    Good-Ark
    Package
    SOD-123F
    Pins
    2
    Details
    Schottky diode, 40 V, 1 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • G1214TA2UfSOT-353Operational amplifier, 5 pins, Global Mixed-mode TechnologyOperational amplifierSOT-3535 pinsGlobal Mixed-mode Technology
    What it is
    Operational amplifier
    Maker
    Global Mixed-mode Technology
    Package
    SOT-353
    Pins
    5
    Details
    Rail-to-Rail I/O, High-Slew-Rate OP Amp
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • LM3Z30VPT1GSOD-323Zener diode, 2 pins, LRCZener diodeSOD-3232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-323
    Pins
    2
    Details
    Zener diode, VZ Min 28 V, VZ Nom 30 V, VZ Max 32 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • LM3Z30VT1GSOD-323Zener diode, 2 pins, LRCZener diodeSOD-3232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-323
    Pins
    2
    Details
    Zener diode, VZ Min 28 V, VZ Nom 30 V, VZ Max 32 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • LM5Z30VPT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
    What it is
    Zener diode
    Maker
    LRC
    Package
    SOD-523
    Pins
    2
    Details
    Zener diode, VZ Min 28 V, VZ Nom 30 V, VZ Max 32 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 7 more parts have no package on record
    • FM140-MHTSchottky diode, Formosa MicrosemiSchottky diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM140-MHT-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM140-MSSchottky diode, Formosa MicrosemiSchottky diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM140-MS-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM140-MSTSchottky diode, Formosa MicrosemiSchottky diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM140-MST-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • FM140-NSSchottky diode, Formosa MicrosemiSchottky diodeNot recordedNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.