SMD code 16A
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
16A on a chip resistor
143 Ω
143 Ω resistor, 1%
EIA-96 precision code: 16 stands for 143 in the E96 table, and the letter A is the multiplier, × 1. These are 1% parts.
Check it with a meter
Lift one end and measure across it. A good one reads 143 Ω within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 143 Ω on the board is a fault. Open, or well above 143 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 143 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.
On a transistor or diode body (SOT-23-5, SMB, SMA), 16A is a part code instead. Those parts are listed below.
71 parts are printed 16A
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
1.5SMC16ASMCTVS diode, 2 pins, DOWOTVS diodeSMC2 pinsDOWO
- What it is
- TVS diode
- Maker
- DOWO
- Package
- SMC
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
2SD1616A-GSOT-89NPN transistor, 3 pins, Galaxy MicroelectronicsNPN transistorSOT-893 pinsGalaxy Microelectronics
- What it is
- NPN transistor
- Maker
- Galaxy Microelectronics
- Package
- SOT-89
- Pins
- 3
- Details
- 60V, 1A, General Purpose NPN Bipolar Transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
2SD1616A-YSOT-89NPN transistor, 3 pins, Galaxy MicroelectronicsNPN transistorSOT-893 pinsGalaxy Microelectronics
- What it is
- NPN transistor
- Maker
- Galaxy Microelectronics
- Package
- SOT-89
- Pins
- 3
- Details
- 60V, 1A, General Purpose NPN Bipolar Transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
3.0SMC16ASMCTVS diode, 2 pins, YFWTVS diodeSMC2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMC
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
A3.0SMBJ16A-HFSMBTVS diode, 2 pins, ComchipTVS diodeSMB2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMB
- Pins
- 2
- Details
- 16 V 3000 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GSF2TVS16ASOD-123FTVS diode, 2 pins, Good-ArkTVS diodeSOD-123F2 pinsGood-Ark
- What it is
- TVS diode
- Maker
- Good-Ark
- Package
- SOD-123F
- Pins
- 2
- Details
- TVS diode, 200 W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LD8116AGLSOT-23-6LED driver, 6 pins, LeadtrendLED driverSOT-23-66 pinsLeadtrend
- What it is
- LED driver
- Maker
- Leadtrend
- Package
- SOT-23-6
- Pins
- 6
- Details
- Flexible Dimming Solution by PWM / 0-10V / Potentiometer
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
LMBZ16VATLT1GSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ Min 16 V, VZ Nom 15.68 V, VZ Max 16.32 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMBT1616ASOT-23NPN transistor, 3 pins, Galaxy MicroelectronicsNPN transistorSOT-233 pinsGalaxy Microelectronics
- What it is
- NPN transistor
- Maker
- Galaxy Microelectronics
- Package
- SOT-23
- Pins
- 3
- Details
- 60V, 1A, General Purpose NPN Bipolar Transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
MMBT1616A-CSOT-23Transistor, 3 pins, SeCoSTransistorSOT-233 pinsSeCoS
- What it is
- Transistor
- Maker
- SeCoS
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor.
MMBZ16VALSOT-23Zener diode, 3 pins, JieJieZener diodeSOT-233 pinsJieJie
- What it is
- Zener diode
- Maker
- JieJie
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMBZH16VALSOT-23Zener diode, 3 pins, onsemiZener diodeSOT-233 pinsonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOT-23
- Pins
- 3
- Details
- Zener Diodes, 24 and 40 Watt Peak Power MMBZHxxxALT1G Series, SZMMBZHxxxALT1G Series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
P4SMA16ASMATVS diode, 2 pins, DOWOTVS diodeSMA2 pinsDOWO
- What it is
- TVS diode
- Maker
- DOWO
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
P4SMAJ16ASMATVS diode, 2 pins, Taitron ComponentsTVS diodeSMA2 pinsTaitron Components
- What it is
- TVS diode
- Maker
- Taitron Components
- Package
- SMA
- Pins
- 2
- Details
- SMD TVS - 400W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
1 more part has no package on record
1.5SMCJ16ATVS diode, Taitron ComponentsTVS diodeNot recordedNot recordedTaitron Components
- What it is
- TVS diode
- Maker
- Taitron Components
- Package
- Not recorded
- Pins
- Not recorded
- Details
- SMD TVS - 1500W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
NPN transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Bipolar transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 16A
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.