5 parts are printed 2062

Not sure which one you have?

Answer up to 4 quick questions and these 5 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 1SMAF2EZ62SMAFZener diode, 2 pins, RectronZener diodeSMAF2 pinsRectron
    What it is
    Zener diode
    Maker
    Rectron
    Package
    SMAF
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 1SMB2EZ62SMBZener diode, 2 pins, PanjitZener diodeSMB2 pinsPanjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SMB
    Pins
    2
    Details
    Z-diode: 62V±5%, 2W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • TPS2062DSOT-23Load switch, 3 pins, Texas InstrumentsLoad switchSOT-233 pinsTexas Instruments
    What it is
    Load switch
    Maker
    Texas Instruments
    Package
    SOT-23
    Pins
    3
    Details
    Power switch
    Source
    Published code list

    Is it dead? The meter test is below: Load switch.

  • TPS2062DGNMSOP-8Load switch, 8 pins, Texas InstrumentsLoad switchMSOP-88 pinsTexas Instruments
    What it is
    Load switch
    Maker
    Texas Instruments
    Package
    MSOP-8
    Pins
    8
    Details
    Power switch
    Source
    Published code list

    Is it dead? The meter test is below: Load switch.

  • ZXTC2062E6SOT-23-66 pins, Diodes IncorporatedNot recordedSOT-23-66 pinsDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-23-6
    Pins
    6
    Details
    T1 npn T2 pnp comp pair 20V
    Source
    Published code list

    Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 2062

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with 2062

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.