26A on a chip resistor

182 Ω

182 Ω resistor, 1%

EIA-96 precision code: 26 stands for 182 in the E96 table, and the letter A is the multiplier, × 1. These are 1% parts.

Check it with a meter

Lift one end and measure across it. A good one reads 182 Ω within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 182 Ω on the board is a fault. Open, or well above 182 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 182 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (USP-6B, SOT-23-5, SOD-123F), 26A is a part code instead. Those parts are listed below.

Not sure which one you have?

Answer up to 4 quick questions and these 39 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • IXD1216D712PRSOT-893 pins, IXYSNot recordedSOT-893 pinsIXYS
    What it is
    Not recorded
    Maker
    IXYS
    Package
    SOT-89
    Pins
    3
    Details
    Linear voltage regulator IC: 7.1V±2%, 150mA
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • KIC3211SN26SONLDO regulator, KECLDO regulatorSONNot recordedKEC
    What it is
    LDO regulator
    Maker
    KEC
    Package
    SON
    Pins
    Not recorded
    Details
    Linear voltage regulator IC: LDO, 2.6V±1%, 150mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • MMF26ASOD-123FTVS diode, 2 pins, Shanghai SemitechTVS diodeSOD-123F2 pinsShanghai Semitech
    What it is
    TVS diode
    Maker
    Shanghai Semitech
    Package
    SOD-123F
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=26V, Vbr=28.9..33.2V, Ipp=4.8A, 200W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • P4SMAFJ26ASMAFTVS diode, 2 pins, Dongguan You Feng Wei ElectronicsTVS diodeSMAF2 pinsDongguan You Feng Wei Electronics
    What it is
    TVS diode
    Maker
    Dongguan You Feng Wei Electronics
    Package
    SMAF
    Pins
    2
    Details
    TVS diode, unidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • P4SMAJ26ASMA2 pins, YeashinNot recordedSMA2 pinsYeashin
    What it is
    Not recorded
    Maker
    Yeashin
    Package
    SMA
    Pins
    2
    Details
    TVS: 26V, 9.5A, 400W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • P4SMFJ26ASOD-123FTVS diode, 2 pins, YeashinTVS diodeSOD-123F2 pinsYeashin
    What it is
    TVS diode
    Maker
    Yeashin
    Package
    SOD-123F
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=26V, Ipp=9.5A, 400W (1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • P2600SAASMA2 pins, VishayNot recordedSMA2 pinsVishay
    What it is
    Not recorded
    Maker
    Vishay
    Package
    SMA
    Pins
    2
    Details
    Thyristor surge protector: Vdrm=220V, Vs=300V, Ipp=35A(1ms), Bidir.
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • S-1335B10-N4T1U3SOT-3434 pins, ABLICNot recordedSOT-3434 pinsABLIC
    What it is
    Not recorded
    Maker
    ABLIC
    Package
    SOT-343
    Pins
    4
    Details
    equivalent [1.0V LDO]
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • SMAJ26ASMATVS diode, 2 pins, SynSemiTVS diodeSMA2 pinsSynSemi
    What it is
    TVS diode
    Maker
    SynSemi
    Package
    SMA
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMBG26ASMBGTVS diode, 2 pins, Microsemi Integrated Products DivisionTVS diodeSMBG2 pinsMicrosemi Integrated Products Division
    What it is
    TVS diode
    Maker
    Microsemi Integrated Products Division
    Package
    SMBG
    Pins
    2
    Details
    600 W TVS diode, unidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMBJ26ASMBTVS diode, 2 pins, SynSemiTVS diodeSMB2 pinsSynSemi
    What it is
    TVS diode
    Maker
    SynSemi
    Package
    SMB
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMCJ26ASMCTVS diode, 2 pins, SynSemiTVS diodeSMC2 pinsSynSemi
    What it is
    TVS diode
    Maker
    SynSemi
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 3 more parts have no package on record
    • KIC3210T-026LDO regulator, KECLDO regulatorNot recordedNot recordedKEC
      What it is
      LDO regulator
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 2.6V±1%, 150mA, +CE
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • KIC3211T26LDO regulator, KECLDO regulatorNot recordedNot recordedKEC
      What it is
      LDO regulator
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 2.6V±1%, 150mA, +CE
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • S-1335B10-A4T2U34 pins, ABLICNot recordedNot recorded4 pinsABLIC
      What it is
      Not recorded
      Maker
      ABLIC
      Package
      Not recorded
      Pins
      4
      Details
      equivalent [1.0V LDO]
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.