Skip to content

SMD code 2

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • HVE200ASOD-5232 pins, HitachiNot recordedSOD-5232 pinsHitachi
    What it is
    Not recorded
    Maker
    Hitachi
    Package
    SOD-523
    Pins
    2
    Details
    Диод (Diode)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • HVR100SOD-1232 pins, HitachiNot recordedSOD-1232 pinsHitachi
    What it is
    Not recorded
    Maker
    Hitachi
    Package
    SOD-123
    Pins
    2
    Details
    C-diode: AM-Tuning, 421..524pF(1V)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • HVU200SOD-3232 pins, HitachiNot recordedSOD-3232 pinsHitachi
    What it is
    Not recorded
    Maker
    Hitachi
    Package
    SOD-323
    Pins
    2
    Details
    Диод (Diode)
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • MAZS027SOD-5232 pinsNot recordedSOD-5232 pinsNot recorded
    What it is
    Not recorded
    Maker
    Not recorded
    Package
    SOD-523
    Pins
    2
    Details
    Z-diode: 2,5..2,9V, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • MAZS0270LSOD-5232 pins, PanNot recordedSOD-5232 pinsPan
    What it is
    Not recorded
    Maker
    Pan
    Package
    SOD-523
    Pins
    2
    Details
    Z-diode: 2,5..2,75V, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • MMPZ5223SPTSOD-323Zener diode, 2 pins, Chenmko EnterpriseZener diodeSOD-3232 pinsChenmko Enterprise
    What it is
    Zener diode
    Maker
    Chenmko Enterprise
    Package
    SOD-323
    Pins
    2
    Details
    Zener diode: 2.646..2.754V, Izt=5mA, Zzt=100, 225mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • MMSZ5244BPTSOD-523Zener diode, 2 pins, Chenmko EnterpriseZener diodeSOD-5232 pinsChenmko Enterprise
    What it is
    Zener diode
    Maker
    Chenmko Enterprise
    Package
    SOD-523
    Pins
    2
    Details
    Zener diode: 14V±5%, Izt=9mA, Zzt=15, 225mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • MRF5711LSOT-1434 pins, onsemiNot recordedSOT-1434 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-143
    Pins
    4
    Details
    npn RF MRF571
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • NL17SG02AMUDFNonsemiNot recordedDFNNot recordedonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    DFN
    Pins
    Not recorded
    Details
    CMOS logic IC: 2-input NOR gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • NL17SZ14P5SOT-953Logic gate, 5 pins, onsemiLogic gateSOT-9535 pinsonsemi
    What it is
    Logic gate
    Maker
    onsemi
    Package
    SOT-953
    Pins
    5
    Details
    Single Inverter with Schmitt Trigger
    Source
    An older or alternative marking, from a published code list

    Is it dead? The meter test is below: Integrated circuit.

  • NL17SZ14P5T5GSOT-9535 pins, onsemiNot recordedSOT-9535 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-953
    Pins
    5
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • NLU1G08MUDFNonsemiNot recordedDFNNot recordedonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    DFN
    Pins
    Not recorded
    Details
    CMOS logic IC: 2-input AND gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • NLU1G08MUTCGDFN6 pins, onsemiNot recordedDFN6 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    DFN
    Pins
    6
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • 2 more parts have no package on record
    • HVD132HitachiNot recordedNot recordedNot recordedHitachi
      What it is
      Not recorded
      Maker
      Hitachi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Диод (Diode)
      Source
      Published code list

      Is it dead? The meter test is below: Silicon diode.

    • MA4L728PanasonicNot recordedNot recordedNot recordedPanasonic
      What it is
      Not recorded
      Maker
      Panasonic
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Diode: SBD Sw, 30V, 30mA, Vf<1V(30mA), 1.5pF
      Source
      Published code list

      Is it dead? The meter test is below: Silicon diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.