SMD marking
2Kin SOD-323
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.
3 parts are printed 2K
Not sure which one you have?
Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.
MM3Z20SOD-323Zener diode, 2 pins, DiotecZener diode2 pinsDiotec
- What it is
- Zener diode
- Maker
- Diotec
- Package
- SOD-323
- Pins
- 2
- Details
- SMD Planar Zener Diodes
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2 more parts have no package on record. Nothing rules them out, so they stay.
ESDB24DESD protection diode, DiotecESD protection diodeNot recordedDiotec
- What it is
- ESD protection diode
- Maker
- Diotec
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD Protection Diodes in SMD
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
VESD33C1-HD1ESD protection diode, VishayESD protection diodeNot recordedVishay
- What it is
- ESD protection diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Single-Line ESD-Protection Diode in DFN1006-2A
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
3 more parts are printed with a code easy to misread as 2K
Printed with a code easy to misread
One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.
PDZ15Bprinted ZKSOD-323Zener diode, 2 pins, PanjitZener diode2 pinsPanjit
Printed ZK on the part. Easy to misread as 2K. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDZ15B-AUprinted ZKSOD-323Zener diode, 2 pins, PanjitZener diode2 pinsPanjit
Printed ZK on the part. Easy to misread as 2K. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
1 more part has no package on record. Nothing rules them out, so they stay.
TPS3839E16DQNprinted ZKVoltage supervisor, 4 pins, Texas InstrumentsVoltage supervisor4 pinsTexas Instruments
Printed ZK on the part. Easy to misread as 2K. Check that character with a loupe before you order anything.
- What it is
- Voltage supervisor
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- 150-nA, Ultralow Power, Supply Voltage Monitor
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
31 more parts have codes that begin with 2K
Codes that begin with 2K
For a marking with its end worn or burnt off. Each one shows its full printed code.
TVS diode, all Vishay.
2KDFN12Aprinted 2KNA
Printed 2KNA. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN12CAprinted 2KNA
Printed 2KNA. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN13Aprinted 2KNB
Printed 2KNB. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN13CAprinted 2KNB
Printed 2KNB. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN15Aprinted 2KNC
Printed 2KNC. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN15CAprinted 2KNC
Printed 2KNC. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN16Aprinted 2KND
Printed 2KND. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN16CAprinted 2KND
Printed 2KND. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN18Aprinted 2KNE
Printed 2KNE. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN18CAprinted 2KNE
Printed 2KNE. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN20Aprinted 2KNF
Printed 2KNF. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN20CAprinted 2KNF
Printed 2KNF. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN22Aprinted 2KNG
Printed 2KNG. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN22CAprinted 2KNG
Printed 2KNG. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN24Aprinted 2KNH
Printed 2KNH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN24CAprinted 2KNH
Printed 2KNH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN27CAprinted 2KNJ
Printed 2KNJ. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN30CAprinted 2KNK
Printed 2KNK. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN33CAprinted 2KNL
Printed 2KNL. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN36CAprinted 2KNM
Printed 2KNM. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN39CAprinted 2KNN
Printed 2KNN. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN43CAprinted 2KNP
Printed 2KNP. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN47CAprinted 2KNQ
Printed 2KNQ. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN51CAprinted 2KNR
Printed 2KNR. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN56CAprinted 2KNS
Printed 2KNS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN62CAprinted 2KNT
Printed 2KNT. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN68CAprinted 2KNU
Printed 2KNU. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN75CAprinted 2KNV
Printed 2KNV. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN82CAprinted 2KNW
Printed 2KNW. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN91CAprinted 2KNX
Printed 2KNX. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2KDFN100CAprinted 2KNY
Printed 2KNY. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 2000 W TVS diode, bidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Open this in the search to correct a character or try another package.