SMD marking

30in SOT-323

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

Not sure which one you have?

Answer up to 4 quick questions and these 6 parts are ranked, with a meter test that settles it. It works on a dead part too.

The only part printed 30 in this package in our tables

PDTC114YU

What it is
Digital transistor (NPN, resistors built in)
Maker
Nexperia
Package
SOT-323
Pins
3
Details
50 V, 100 mA NPN resistor-equipped transistor; R1 = 10 kΩ, R2 = 47 kΩ
Source
From the manufacturer's datasheet

Is it dead?

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board:
On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread

These parts are printed with a character that is easy to misread as what you typed. The odd one out is marked on each.

  • RB715Fprinted 3DSOT-323Schottky diode, JSCJ

    Printed 3D on the part. Easy to misread as 30. Check that character with a loupe before you order anything.

    What it is
    Schottky diode
    Maker
    JSCJ
    Package
    SOT-323
    Pins
    3
    Details
    Schottky diode, 40 V, 0.03 A
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 4 more parts have no package on record. Nothing rules them out, so they stay.
    • PESD5V0V1BLSprinted 3QESD protection diode, Nexperia

      Printed 3Q on the part. Easy to misread as 30. Check that character with a loupe before you order anything.

      What it is
      ESD protection diode
      Maker
      Nexperia
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Very low capacitance bidirectional ESD protection diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • RB715Wprinted 3DSwitching diode, JSCJ

      Printed 3D on the part. Easy to misread as 30. Check that character with a loupe before you order anything.

      What it is
      Switching diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Switching diode, 40 V, 30 mA
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways: failed open.
      • A reading the wrong way round as well: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • VESD14D1-HD1printed 3DESD protection diode, Vishay

      Printed 3D on the part. Easy to misread as 30. Check that character with a loupe before you order anything.

      What it is
      ESD protection diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Single-Line ESD-Protection Diode in DFN1006-2A
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • VESD26D1-HD1printed 3OESD protection diode, Vishay

      Printed 3O on the part. Easy to misread as 30. Check that character with a loupe before you order anything.

      What it is
      ESD protection diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Single-Line ESD-Protection Diode in DFN1006-2A
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

13 more parts have codes that begin with 30

Codes that begin with 30

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • TLV803EA30DCKprinted 30ASOT-323Voltage supervisor, Texas Instruments

    Printed 30A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage supervisor
    Maker
    Texas Instruments
    Package
    SOT-323
    Pins
    3
    Details
    Low Power 250-nA IQ and Small Size Supply Voltage Supervisors
    Source
    From the manufacturer's datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 12 more parts have no package on record. Nothing rules them out, so they stay.
    • 1SMB3EZ30printed 30BZener diode, Panjit

      Printed 30B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 1SMB3EZ30-AUprinted 30BZener diode, Panjit

      Printed 30B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AONR30310printed 30310MOSFET, Alpha & Omega Semiconductor

      Printed 30310. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Low-voltage (12-30 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AONS30306printed 30306MOSFET, Alpha & Omega Semiconductor

      Printed 30306. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Low-voltage (12-30 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CJM3005printed 3005N-channel MOSFET, JSCJ

      Printed 3005. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      N-channel MOSFET
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MOSFET, N-channel, 30 V, 5 A
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESDUNH30VF1printed 30PESD protection diode, JSCJ

      Printed 30P. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      ESD protection diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 30 V
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESDUNK30VC1printed 30AFESD protection diode, JSCJ

      Printed 30AF. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      ESD protection diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 30 V
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ30Aprinted 30AZener diode, Vishay

      Printed 30A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      30 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ30Bprinted 30BZener diode, Vishay

      Printed 30B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      30 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ30Cprinted 30CZener diode, Vishay

      Printed 30C. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      30 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ30Dprinted 30DZener diode, Vishay

      Printed 30D. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      30 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SMPZ3930Bprinted 30BZener diode, Vishay

      Printed 30B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      16 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Open this in the search to correct a character or try another package.