Skip to content

SMD code 3324

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

3324 on a chip resistor

3.32 MΩ

3.32 MΩ resistor, 1%

332 followed by 4 zeros. Four digits is normally the 1% series.

Check it with a meter

Lift one end and measure across it. A good one reads 3.32 MΩ within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 3.32 MΩ on the board is a fault. Open, or well above 3.32 MΩ, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 3.32 MΩ. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (DFN, SOT-23), 3324 is a part code instead. Those parts are listed below.

3 parts are printed 3324

Not sure which one you have?

Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • LST3324ADFNESD protection diode, Galaxy MicroelectronicsESD protection diodeDFNGalaxy Microelectronics
    What it is
    ESD protection diode
    Maker
    Galaxy Microelectronics
    Package
    DFN
    Pins
    Not recorded
    Details
    3.3V, 50W, Surface Mount TVS
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SSF3324SOT-23N-channel MOSFET, Good-ArkN-channel MOSFETSOT-23Good-Ark
    What it is
    N-channel MOSFET
    Maker
    Good-Ark
    Package
    SOT-23
    Pins
    3
    Details
    N-channel MOSFET, 30 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: N-channel MOSFET.

  • 1 more part has no package on record

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

N-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Codes that begin with 3324

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.