SMD code 336
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
336 on a chip resistor
33 MΩ
33 MΩ resistor, 5%
33 followed by 6 zeros. Three digits is normally the 5% series. The same marking also reads as 33 µF on a capacitor, and nothing in the code says which; the body of the part does.
Other readings of the same characters, most likely first
- 33 µF capacitor
Check it with a meter
Lift one end and measure across it. A good one reads 33 MΩ within 5%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 33 MΩ on the board is a fault. Open, or well above 33 MΩ, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 33 MΩ. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.
On a transistor or diode body (SOT-23, SMB, SMC), 336 is a part code instead. Those parts are listed below.
16 parts are printed 336
Not sure which one you have?
Answer up to 4 quick questions and these 16 parts are ranked, with a meter test that settles it. It works on a dead part too.
FDN336PSOT-23P-channel MOSFET, 3 pins, onsemiP-channel MOSFETSOT-233 pinsonsemi
- What it is
- P-channel MOSFET
- Maker
- onsemi
- Package
- SOT-23
- Pins
- 3
- Details
- MOSFET - Single P-Channel POWERTRENCH
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: P-channel MOSFET.
GSEDC36U500SOD-323ESD protection diode, 2 pins, Good-ArkESD protection diodeSOD-3232 pinsGood-Ark
- What it is
- ESD protection diode
- Maker
- Good-Ark
- Package
- SOD-323
- Pins
- 2
- Details
- ESD protection diode, VRWM 36 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
HE6336MMGSOT-323LDO regulator, 3 pins, Heermicr SemicconductorLDO regulatorSOT-3233 pinsHeermicr Semicconductor
- What it is
- LDO regulator
- Maker
- Heermicr Semicconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Linear voltage regulator IC: LDO, 3.6V±2%, 250mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
HE6336MNGSOT-23LDO regulator, 3 pins, Heermicr SemicconductorLDO regulatorSOT-233 pinsHeermicr Semicconductor
- What it is
- LDO regulator
- Maker
- Heermicr Semicconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Linear voltage regulator IC: LDO, 3.6V±2%, 250mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
HE732536MM3SOT-23LDO regulator, 3 pins, Heermicr SemicconductorLDO regulatorSOT-233 pinsHeermicr Semicconductor
- What it is
- LDO regulator
- Maker
- Heermicr Semicconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Linear voltage regulator IC: LDO, 3.6V±2%, 250mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
HM732536MRSOT-23LDO regulator, 3 pins, Huamei SemiconductorLDO regulatorSOT-233 pinsHuamei Semiconductor
- What it is
- LDO regulator
- Maker
- Huamei Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Linear voltage regulator IC: LDO, 3.6V±2%, 300mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
LN3526N3342MSOT-143Voltage supervisor, 4 pins, Shanghai Natlinear ElectronicsVoltage supervisorSOT-1434 pinsShanghai Natlinear Electronics
- What it is
- Voltage supervisor
- Maker
- Shanghai Natlinear Electronics
- Package
- SOT-143
- Pins
- 4
- Details
- Voltage detector IC: 3.3V±2%, -Reset ODO, -MR, 400ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
NDS336NSOT-233 pins, onsemiNot recordedSOT-233 pinsonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- SOT-23
- Pins
- 3
- Details
- p-ch mosfet 0.27A, 1.2A pk, 20V
- Source
- Published code list
Is it dead? The meter test is below: P-channel MOSFET.
NDS336PSOT-233 pins, National SemiconductorNot recordedSOT-233 pinsNational Semiconductor
- What it is
- Not recorded
- Maker
- National Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- p-MOS-e: V-MOS, LogL, 20V, 1,2A, <0,27Ω
- Source
- Published code list
Is it dead? The meter test is below: This part.
R1126N361DSOT-23-55 pins, Nisshinbo Micro DevicesNot recordedSOT-23-55 pinsNisshinbo Micro Devices
- What it is
- Not recorded
- Maker
- Nisshinbo Micro Devices
- Package
- SOT-23-5
- Pins
- 5
- Details
- VR-IC: LDO, LN, CE, auto discharge, 3.6V±2%, 150mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
R3112N361CSOT-23-55 pins, Nisshinbo Micro DevicesNot recordedSOT-23-55 pinsNisshinbo Micro Devices
- What it is
- Not recorded
- Maker
- Nisshinbo Micro Devices
- Package
- SOT-23-5
- Pins
- 5
- Details
- CMOS-IC: Voltage Detector 3,6V, Reset Open drain output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6104A437MRSOT-23-5Voltage supervisor, 5 pins, TorexVoltage supervisorSOT-23-55 pinsTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-23-5
- Pins
- 5
- Details
- CMOS-IC: VDet 3.7V, 5%, Hst, ±Reset PPO, Wt=200ms, Rt=3.13ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6203E372FRSOT-223TorexNot recordedSOT-223Not recordedTorex
- What it is
- Not recorded
- Maker
- Torex
- Package
- SOT-223
- Pins
- Not recorded
- Details
- VR-IC: 3.7V±2%, 400mA
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6203E372MRSOT-233 pins, TorexNot recordedSOT-233 pinsTorex
- What it is
- Not recorded
- Maker
- Torex
- Package
- SOT-23
- Pins
- 3
- Details
- VR-IC: 3.7V±2%, 400mA
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6203E372PRSOT-893 pins, TorexNot recordedSOT-893 pinsTorex
- What it is
- Not recorded
- Maker
- Torex
- Package
- SOT-89
- Pins
- 3
- Details
- VR-IC: 3.7V±2%, 400mA
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
P-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 336
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 4 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.