Skip to content

SMD marking

34Ain SOT-323

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

The only part printed 34A in this package in our tables

TLV803EA24DCK

What it is
Voltage supervisor
Maker
Texas Instruments
Package
SOT-323
Pins
3
Details
Low Power 250-nA IQ and Small Size Supply Voltage Supervisors
Source
From the manufacturer's datasheet

Is it dead?

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

1 more part has a code that begins with 34A

Codes that begin with 34A

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • SS34ALHprinted 34ALHSchottky diode, Taiwan Semiconductor

    Printed 34ALH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Schottky diode
    Maker
    Taiwan Semiconductor
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Rectifier schottky
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Open this in the search to correct a character or try another package.