Skip to content

SMD code 36C

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

36C on a chip resistor

23.2 kΩ

23.2 kΩ resistor, 1%

EIA-96 precision code: 36 stands for 232 in the E96 table, and the letter C is the multiplier, × 100. These are 1% parts.

Check it with a meter

Lift one end and measure across it. A good one reads 23.2 kΩ within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 23.2 kΩ on the board is a fault. Open, or well above 23.2 kΩ, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 23.2 kΩ. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (SMC, USP-6B, USP-6C), 36C is a part code instead. Those parts are listed below.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • SMF36CASOD-123FTVS diode, 2 pins, JieJieTVS diodeSOD-123F2 pinsJieJie
    What it is
    TVS diode
    Maker
    JieJie
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TDLC36CSOD-323ESD protection diode, 2 pins, Galaxy MicroelectronicsESD protection diodeSOD-3232 pinsGalaxy Microelectronics
    What it is
    ESD protection diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-323
    Pins
    2
    Details
    36V, 350W, Surface Mount TVS
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • VCAN36C2-03GSOT-323ESD protection diode, 3 pins, VishayESD protection diodeSOT-3233 pinsVishay
    What it is
    ESD protection diode
    Maker
    Vishay
    Package
    SOT-323
    Pins
    3
    Details
    Bidirectional Symmetrical (BiSy) Low Capacitance, Dual-Line ESD Protection Diode in SOT-323
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • HP6SMB36CAE352SMBTVS diode, 2 pins, HXYTVS diodeSMB2 pinsHXY
    What it is
    TVS diode
    Maker
    HXY
    Package
    SMB
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • HSZP6SMB36CAT3GSMBTVS diode, 2 pins, HXYTVS diodeSMB2 pinsHXY
    What it is
    TVS diode
    Maker
    HXY
    Package
    SMB
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • P6SMB36CA-E3/52SMBTVS diode, 2 pins, HXYTVS diodeSMB2 pinsHXY
    What it is
    TVS diode
    Maker
    HXY
    Package
    SMB
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SZP6SMB36CAT3GSMBTVS diode, 2 pins, HXYTVS diodeSMB2 pinsHXY
    What it is
    TVS diode
    Maker
    HXY
    Package
    SMB
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • AAT60036C-S2SOT-23Voltage supervisor, 3 pins, Advanced Analog TechnologyVoltage supervisorSOT-233 pinsAdvanced Analog Technology
    What it is
    Voltage supervisor
    Maker
    Advanced Analog Technology
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 3.6V±1%, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AAT60036C-S5SOT-23-5Voltage supervisor, 5 pins, Advanced Analog TechnologyVoltage supervisorSOT-23-55 pinsAdvanced Analog Technology
    What it is
    Voltage supervisor
    Maker
    Advanced Analog Technology
    Package
    SOT-23-5
    Pins
    5
    Details
    Voltage detector IC: 3.6V±1%, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AAT60036C-S15SOT-143Voltage supervisor, 4 pins, Advanced Analog TechnologyVoltage supervisorSOT-1434 pinsAdvanced Analog Technology
    What it is
    Voltage supervisor
    Maker
    Advanced Analog Technology
    Package
    SOT-143
    Pins
    4
    Details
    Voltage detector IC: 3.6V±1%, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AAT60036C-S16SOT-89Voltage supervisor, 3 pins, Advanced Analog TechnologyVoltage supervisorSOT-893 pinsAdvanced Analog Technology
    What it is
    Voltage supervisor
    Maker
    Advanced Analog Technology
    Package
    SOT-89
    Pins
    3
    Details
    Voltage detector IC: 3.6V±1%, -Reset ODO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • GLZ36CSOD-80Zener diode, 2 pins, PanjitZener diodeSOD-802 pinsPanjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-80
    Pins
    2
    Details
    Zener diode: 33.40..35.13V, Zzt=75 , Izt=5mA, 500mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • P4SMA36CSMA2 pins, EIC SemiconductorNot recordedSMA2 pinsEIC Semiconductor
    What it is
    Not recorded
    Maker
    EIC Semiconductor
    Package
    SMA
    Pins
    2
    Details
    TVS: 36V, 8A, 400W (1ms), Bidirectional
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • P4SMAFJ36CSMAFTVS diode, 2 pins, Dongguan You Feng Wei ElectronicsTVS diodeSMAF2 pinsDongguan You Feng Wei Electronics
    What it is
    TVS diode
    Maker
    Dongguan You Feng Wei Electronics
    Package
    SMAF
    Pins
    2
    Details
    Transient voltage supressor: Vrwm=36V, Vbr=40..50.7V, Ipp=6.2A, 400W(1ms), Bidir.
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 1 more part has no package on record
    • HZF36CPZener diode, RenesasZener diodeNot recordedNot recordedRenesas
      What it is
      Zener diode
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Z-diode: 36V±10%, 900mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.