SMD code 3C in SOT-143

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 24 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • R3132Q42EASOT-1434 pins, Nisshinbo Micro DevicesNot recorded4 pinsNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-143
    Pins
    4
    Details
    CMOS-IC: Voltage Detector 4,2V, MR, -Reset Push-pull output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • RQ5RW32AASOT-1434 pins, Nisshinbo Micro DevicesNot recorded4 pinsNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-143
    Pins
    4
    Details
    VR-IC: LDO, -CE, 3.2V±2%, 150mA
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • 13 more parts have no package on record. Nothing rules them out, so they stay.
    • NCV8170BMX120LDO regulator, onsemiLDO regulatorNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LDO Regulator - Ultra-Low I CMOS
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • SGM431LXXDH4GVoltage reference, 4 pins, SG MicroVoltage reference4 pinsSG Micro
      What it is
      Voltage reference
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      4
      Details
      Precision Programmable Reference
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • SGM2038-1.1XUDY4GLDO regulator, 4 pins, SG MicroLDO regulator4 pinsSG Micro
      What it is
      LDO regulator
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      4
      Details
      1.1 V output, 500mA, Low Noise, Very Low Dropout Bias Rail CMOS Voltage Regulator
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • AP7340D-15FS4-7RLDO regulator, Diodes IncorporatedLDO regulatorNot recordedDiodes Incorporated
      What it is
      LDO regulator
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 1.5V±1%, 150mA, +CE, CL
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • CDZ55C3V3TZener diode, Crownpo TechnologyZener diodeNot recordedCrownpo Technology
      What it is
      Zener diode
      Maker
      Crownpo Technology
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 3.14..3.47V, Zzt=85, Izt=5mA, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • HZU3CLLZener diode, RenesasZener diodeNot recordedRenesas
      What it is
      Zener diode
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 3.1..3.5V, Izt=0.5mA, Zzt=360, 150mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • IXD5127N19DNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.9V±0.8%, -Reset ODO, -MR, 400ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • R1161D231ANisshinbo Micro DevicesNot recordedNot recordedNisshinbo Micro Devices
      What it is
      Not recorded
      Maker
      Nisshinbo Micro Devices
      Package
      Not recorded
      Pins
      Not recorded
      Details
      VR-IC: LDO, -CE, 2.3V±2%, 350mA
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • RKZ3C1KDZener diode, RenesasZener diodeNot recordedRenesas
      What it is
      Zener diode
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 3.1..3.3V, Izt=5mA, Zzt=100, 500mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • RKZ3C2KDZener diode, RenesasZener diodeNot recordedRenesas
      What it is
      Zener diode
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 3.2..3.4V, Izt=5mA, Zzt=100, 500mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • RKZ3C3KDZener diode, RenesasZener diodeNot recordedRenesas
      What it is
      Zener diode
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 3.3..3.5V, Izt=5mA, Zzt=100, 500mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • XC6127N19DNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.9V±0.8%, -Reset ODO, -MR, Rdt=400ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129C19D9R-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.9V±0.8%, -Reset PPO, Det. Delay, Undef. Protect
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 3C

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 11 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.