  • BC858BSOT-23PNP transistor, Infineon
    What it is
    PNP transistor
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Details
    -30 V PNP small-signal transistor, gain group B
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 2 more parts have no package on record. Nothing rules them out, so they stay.
    • ESD05B1ZESD protection diode, Diotec
      What it is
      ESD protection diode
      Maker
      Diotec
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD Protection Diodes in SMD
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • VESD08D1-HD1ESD protection diode, Vishay
      What it is
      ESD protection diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Single-Line ESD-Protection Diode in DFN1006-2A
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

31 more parts have codes that begin with 3K

Codes that begin with 3K

For a marking with its end worn or burnt off. Each one shows its full printed code.

TVS diode, all Vishay.

  • 3KDFN12Aprinted 3KNA

    Printed 3KNA. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN12CAprinted 3KNA

    Printed 3KNA. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN13Aprinted 3KNB

    Printed 3KNB. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN13CAprinted 3KNB

    Printed 3KNB. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN15Aprinted 3KNC

    Printed 3KNC. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN15CAprinted 3KNC

    Printed 3KNC. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN16Aprinted 3KND

    Printed 3KND. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN16CAprinted 3KND

    Printed 3KND. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN18Aprinted 3KNE

    Printed 3KNE. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN18CAprinted 3KNE

    Printed 3KNE. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN20Aprinted 3KNF

    Printed 3KNF. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN20CAprinted 3KNF

    Printed 3KNF. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN22Aprinted 3KNG

    Printed 3KNG. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN22CAprinted 3KNG

    Printed 3KNG. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN24Aprinted 3KNH

    Printed 3KNH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN24CAprinted 3KNH

    Printed 3KNH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN27CAprinted 3KNJ

    Printed 3KNJ. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN30CAprinted 3KNK

    Printed 3KNK. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN33CAprinted 3KNL

    Printed 3KNL. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN36CAprinted 3KNM

    Printed 3KNM. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN39CAprinted 3KNN

    Printed 3KNN. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN43CAprinted 3KNP

    Printed 3KNP. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN47CAprinted 3KNQ

    Printed 3KNQ. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN51CAprinted 3KNR

    Printed 3KNR. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN56CAprinted 3KNS

    Printed 3KNS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN62CAprinted 3KNT

    Printed 3KNT. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN68CAprinted 3KNU

    Printed 3KNU. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN75CAprinted 3KNV

    Printed 3KNV. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN82CAprinted 3KNW

    Printed 3KNW. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN91CAprinted 3KNX

    Printed 3KNX. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3KDFN100CAprinted 3KNY

    Printed 3KNY. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    3000 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.