SMD code 43-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
145 parts are printed 43-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
TZD4.3WSSOD-323Zener diode, 2 pins, Taitron ComponentsZener diodeSOD-3232 pinsTaitron Components
- What it is
- Zener diode
- Maker
- Taitron Components
- Package
- SOD-323
- Pins
- 2
- Details
- SMD Zener Diodes (Two Terminals) - 200mW
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
TZD4.3WTSOD-523Zener diode, 2 pins, Taitron ComponentsZener diodeSOD-5232 pinsTaitron Components
- What it is
- Zener diode
- Maker
- Taitron Components
- Package
- SOD-523
- Pins
- 2
- Details
- SMD Zener Diodes (Two Terminals) - 150mW
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
WSR4002T0SOT-23Schottky diode, 3 pins, WayonSchottky diodeSOT-233 pinsWayon
- What it is
- Schottky diode
- Maker
- Wayon
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
EIA-96:430603Precision resistor (EIA-96 code), 2 pinsPrecision resistor (EIA-96 code)06032 pinsNot recorded
- What it is
- Precision resistor (EIA-96 code)
- Maker
- Not recorded
- Package
- 0603
- Pins
- 2
- Details
- EIA-96 precision chip resistor, code 43 stands for 274 in the E96 table; the printed mark adds a multiplier letter (43A = 274 Ohm, 43B = 2.74 kOhm)
- Source
- Added by hand from a published table
Is it dead? The meter test is below: Resistor.
AP8822N-13GASOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 1.3V±2%, -Reset ODO, Rdt=200ms, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-13GTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-3233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 1.3V±2%, -Reset ODO, Rdt=200ms, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-13PASOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 1.3V±2%, -Reset ODO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
8 more parts have no package on record
USFZ4.3VZener diode, KECZener diodeNot recordedNot recordedKEC
- What it is
- Zener diode
- Maker
- KEC
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
1PS89SB153 pins, NexperiaNot recordedNot recorded3 pinsNexperia
- What it is
- Not recorded
- Maker
- Nexperia
- Package
- Not recorded
- Pins
- 3
- Details
- Si-diode: Dual, Schottky Barrier, U-Speed, 30V, 200mA, <10pF
- Source
- Published code list
Is it dead? The meter test is below: Schottky diode.
02DZ4.3XZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
- What it is
- Zener diode
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode: 4.00..4.23V, Iz=5mA, Zz=130, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
02DZ4.3YZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
- What it is
- Zener diode
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode: 4.13..4.35V, Iz=5mA, Zz=130, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
02DZ4.3ZZener diode, ToshibaZener diodeNot recordedNot recordedToshiba
- What it is
- Zener diode
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode: 4.25..4.50V, Iz=5mA, Zz=130, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
AP8822N-13GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 1.3V±2%, -Reset ODO, 200ms Rt delay, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-13GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 1.3V±2%, -Reset ODO, 200ms Rt delay, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-13PIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 1.3V±2%, -Reset ODO, 200ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Resistor
Ohms range, across it, power off.
Working, it reads
Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.
Dead, it reads
- Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
- Well above its marked value: drifted high.
- On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
- On the board:
- A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
- Compare:
- The same position on another channel usually carries the same value, and so does the matching part on another board.
- Watch for:
- A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.