102 parts are printed 52-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
S-LBAV199LT1GSOT-23Switching diode, 3 pins, LRCSwitching diodeSOT-233 pinsLRC
- What it is
- Switching diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Switching diode, VR 85 V, IF 215 mA, VF Max 1.25 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
S-LBAV199LT1G-SSOT-23Switching diode, 3 pins, LRCSwitching diodeSOT-233 pinsLRC
- What it is
- Switching diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Switching diode, VR 85 V, IF 215 mA, VF Max 1.25 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
S-LBZT52B3V3T1GSOD-123Zener diode, 2 pins, LRCZener diodeSOD-1232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode, VZ Min 3.32 V, VZ Nom 3.4 V, VZ Max 3.53 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
S-LBZX84B3V3LT1GSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ Min 3.32 V, VZ Nom 3.4 V, VZ Max 3.53 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
S-LBZX84B3V3LT1G-SSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ Min 3.32 V, VZ Nom 3.4 V, VZ Max 3.53 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
S-LEDZ3.3BT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 3.32 V, VZ Nom 3.4 V, VZ Max 3.53 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
S-LMBR0520FT1GSOD-123FSchottky diode, 2 pins, LRCSchottky diodeSOD-123F2 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-123F
- Pins
- 2
- Details
- Schottky diode, VR 20 V, IF 0.5 A, VF Max 0.43 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
S-LUDZS3.3BT1GSOD-323Zener diode, 2 pins, LRCZener diodeSOD-3232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Zener diode, VZ Min 3.32 V, VZ Nom 3.4 V, VZ Max 3.53 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
TDTA123YCASOT-23Digital transistor (PNP, resistors built in), 3 pins, Galaxy MicroelectronicsDigital transistor (PNP, resistors built in)SOT-233 pinsGalaxy Microelectronics
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- Galaxy Microelectronics
- Package
- SOT-23
- Pins
- 3
- Details
- 50V, 100mA, PNP Bipolar Digital Transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
TDTA123YESOT-523Digital transistor (PNP, resistors built in), 3 pins, Galaxy MicroelectronicsDigital transistor (PNP, resistors built in)SOT-5233 pinsGalaxy Microelectronics
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- Galaxy Microelectronics
- Package
- SOT-523
- Pins
- 3
- Details
- 50V, 100mA, PNP Bipolar Digital Transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
TDTA123YUASOT-323Digital transistor (PNP, resistors built in), 3 pins, Galaxy MicroelectronicsDigital transistor (PNP, resistors built in)SOT-3233 pinsGalaxy Microelectronics
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- Galaxy Microelectronics
- Package
- SOT-323
- Pins
- 3
- Details
- 50V, 100mA, PNP Bipolar Digital Transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
UDZ3.3BSOD-323Zener diode, 2 pins, Formosa MicrosemiZener diodeSOD-3232 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
3 more parts have no package on record
RB055L-40DDSchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
S-LMBR0520ET1GSchottky diode, LRCSchottky diodeNot recordedNot recordedLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky diode, VR 20 V, IF 0.5 A, VF Max 0.43 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SGM2031-2.8YUDH4GLDO regulator, 4 pins, SG MicroLDO regulatorNot recorded4 pinsSG Micro
- What it is
- LDO regulator
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 4
- Details
- 2.8 V output, Low Power, Low Dropout, RF Linear Regulator
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.