SMD code 57-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
60 parts are printed 57-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
FSA3157L6XSOT-363Analog switch, 6 pins, HXYAnalog switchSOT-3636 pinsHXY
- What it is
- Analog switch
- Maker
- HXY
- Package
- SOT-363
- Pins
- 6
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
SN74LVC1G3157DCKRSOT-363Analog switch, 6 pins, HXYAnalog switchSOT-3636 pinsHXY
- What it is
- Analog switch
- Maker
- HXY
- Package
- SOT-363
- Pins
- 6
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
EIA-96:570603Precision resistor (EIA-96 code), 2 pinsPrecision resistor (EIA-96 code)06032 pinsNot recorded
- What it is
- Precision resistor (EIA-96 code)
- Maker
- Not recorded
- Package
- 0603
- Pins
- 2
- Details
- EIA-96 precision chip resistor, code 57 stands for 383 in the E96 table; the printed mark adds a multiplier letter (57A = 383 Ohm, 57B = 3.83 kOhm)
- Source
- Added by hand from a published table
Is it dead? The meter test is below: Resistor.
AP8822N-27GASOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, Rdt=200ms, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-27GTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-3233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, Rdt=200ms, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-27PASOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-27PTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-3233 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BSR19ASOT-233 pins, Philips SemiconductorsNot recordedSOT-233 pinsPhilips Semiconductors
- What it is
- Not recorded
- Maker
- Philips Semiconductors
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: Sw, 180V, 600mA, 250mW, B>80, 300
- Source
- Published code list
Is it dead? The meter test is below: This part.
7 more parts have no package on record
74AUP1T17GWNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Schmitt-trigger input buffer with voltage-level translator
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP1T17GXNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: Schmitt-trigger input buffer with voltage-level translator
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-27GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, 200ms Rt delay, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-27GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, 200ms Rt delay, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-27PIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, 200ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-27PSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.7V±2%, -Reset ODO, 200ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BFQ57InfineonNot recordedNot recordedNot recordedInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Details
- npn 6.5GHz 16V/35mA
- Source
- Published code list
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Resistor
Ohms range, across it, power off.
Working, it reads
Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.
Dead, it reads
- Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
- Well above its marked value: drifted high.
- On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
- On the board:
- A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
- Compare:
- The same position on another channel usually carries the same value, and so does the matching part on another board.
- Watch for:
- A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.