SMD code 5A in SOD-323
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
10 parts in SOD-323 are printed 5A
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
1N4151WSSOD-323Switching diode, VishaySwitching diodeVishay
- What it is
- Switching diode
- Maker
- Vishay
- Package
- SOD-323
- Pins
- 2
- Details
- _Small Signal Fast Switching Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
CH601H-90GPSOD-323Schottky diode, ChenmkoSchottky diodeChenmko
- What it is
- Schottky diode
- Maker
- Chenmko
- Package
- SOD-323
- Pins
- 2
- Details
- SCHOTTKY BARRIER DIODE, 90 V, 0.1 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LMDL6050T1GSOD-323Switching diode, LRCSwitching diodeLRC
- What it is
- Switching diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Switching diode, VR 70 V, IF 200 mA, VF Max 1.1 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
PSGP5ASOD-323Rectifier, PrisemiRectifierPrisemi
- What it is
- Rectifier
- Maker
- Prisemi
- Package
- SOD-323
- Pins
- 2
- Details
- Rectifier diode, 1 A, 600 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
S-LMDL6050T1GSOD-323Switching diode, LRCSwitching diodeLRC
- What it is
- Switching diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Switching diode, VR 70 V, IF 200 mA, VF Max 1.1 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
S1JWS-HFSOD-323Rectifier, ComchipRectifierComchip
- What it is
- Rectifier
- Maker
- Comchip
- Package
- SOD-323
- Pins
- 2
- Details
- 600 V, 1 A rectifier
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
SM4005WSSOD-323Rectifier, YFWRectifierYFW
- What it is
- Rectifier
- Maker
- YFW
- Package
- SOD-323
- Pins
- 2
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
CH601H-90PTSOD-323Chenmko EnterpriseNot recordedChenmko Enterprise
- What it is
- Not recorded
- Maker
- Chenmko Enterprise
- Package
- SOD-323
- Pins
- 2
- Details
- Diode: SBD, 90V, 100mA, Vf<0.77V(100mA)
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
MMDL6050SOD-323Galaxy MicroelectronicsNot recordedGalaxy Microelectronics
- What it is
- Not recorded
- Maker
- Galaxy Microelectronics
- Package
- SOD-323
- Pins
- 2
- Details
- Si-diode: Sw, 70V, 200mA, 200mW, Vf<1,1V(100mA), <4ns
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
MMDL6050T1SOD-323onsemiNot recordedonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- SOD-323
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: This part.
5 more parts have no package on record. Nothing rules them out, so they stay.
ACPDWQ5V0P-HFESD protection diode, ComchipESD protection diodeComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 5 V bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
CPDWQ5V0P-HFESD protection diode, ComchipESD protection diodeComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 5 V bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESDNH4V5B1ESD protection diode, JSCJESD protection diodeJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 4.5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESDUNH5V0B1ESD protection diode, JSCJESD protection diodeJSCJ
- What it is
- ESD protection diode
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
GSEN5B200ESD protection diode, Good-ArkESD protection diodeGood-Ark
- What it is
- ESD protection diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 5A
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with 5A
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 187 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.