Skip to content

SMD code 62 in SMC

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 31 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 1.5SMC62SMCTVS diode, HottechTVS diodeHottech
    What it is
    TVS diode
    Maker
    Hottech
    Package
    SMC
    Pins
    2
    Details
    TVS diode, VRWM 50.2 V, unidirectional
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 3.0SMC62SMCTVS diode, YFWTVS diodeYFW
    What it is
    TVS diode
    Maker
    YFW
    Package
    SMC
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 13 more parts have no package on record. Nothing rules them out, so they stay.
    • BAT62-02WSchottky diode, InfineonSchottky diodeInfineon
      What it is
      Schottky diode
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • BAT62-07L4Schottky diode, InfineonSchottky diodeInfineon
      What it is
      Schottky diode
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • CM6200ESD protection diode, onsemiESD protection diodeonsemi
      What it is
      ESD protection diode
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Advance Information EMI Filters with ESD Protection for Microphone Interface
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • EMI4162MUESD protection diode, onsemiESD protection diodeonsemi
      What it is
      ESD protection diode
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Common Mode Filter with ESD Protection
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • USFZ6.2VZener diode, KECZener diodeKEC
      What it is
      Zener diode
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • VSKY1020E6Schottky diode, VishaySchottky diodeVishay
      What it is
      Schottky diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Rectifier Surface-Mount FlipKY Gen 3
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Schottky diode.

    • 02DZ6.2XZener diode, ToshibaZener diodeToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 5.80..6.20V, Iz=5mA, Zz=30, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • 02DZ6.2YZener diode, ToshibaZener diodeToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 6.00..6.39V, Iz=5mA, Zz=30, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • 02DZ6.2ZZener diode, ToshibaZener diodeToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 6.19..6.60V, Iz=5mA, Zz=30, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • AP8822N-32GIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.2V±2%, -Reset ODO, 200ms Rt delay, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8822N-32GSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.2V±2%, -Reset ODO, 200ms Rt delay, H-free
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8822N-32PIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.2V±2%, -Reset ODO, 200ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • AP8822N-32PSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.2V±2%, -Reset ODO, 200ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 62

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 14 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.