SMD code 6Ap
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, p, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and 6A was searched.
147 parts are printed 6Ap
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
S-LBC817-16LT1GSOT-23NPN transistor, 3 pins, LRCNPN transistorSOT-233 pinsLRC
- What it is
- NPN transistor
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor, NPN, IC 500 mA, VCEO 45 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
S-LBC817-16WT1GSOT-323NPN transistor, 3 pins, LRCNPN transistorSOT-3233 pinsLRC
- What it is
- NPN transistor
- Maker
- LRC
- Package
- SOT-323
- Pins
- 3
- Details
- Bipolar transistor, NPN, IC 500 mA, VCEO 45 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
S-LDTA114EN3T5GSOT-883Digital transistor (PNP, resistors built in), 3 pins, LRCDigital transistor (PNP, resistors built in)SOT-8833 pinsLRC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- LRC
- Package
- SOT-883
- Pins
- 3
- Details
- Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
S-LMUN5111T1GSOT-323Digital transistor (PNP, resistors built in), 3 pins, LRCDigital transistor (PNP, resistors built in)SOT-3233 pinsLRC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- LRC
- Package
- SOT-323
- Pins
- 3
- Details
- Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
S-LMUN5111T1G-SSOT-323Digital transistor (PNP, resistors built in), 3 pins, LRCDigital transistor (PNP, resistors built in)SOT-3233 pinsLRC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- LRC
- Package
- SOT-323
- Pins
- 3
- Details
- Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
S1KWS-HFSOD-323Rectifier, 2 pins, ComchipRectifierSOD-3232 pinsComchip
- What it is
- Rectifier
- Maker
- Comchip
- Package
- SOD-323
- Pins
- 2
- Details
- 800 V, 1 A rectifier
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
SBC817-16LSOT-23NPN transistor, 3 pins, onsemiNPN transistorSOT-233 pinsonsemi
- What it is
- NPN transistor
- Maker
- onsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
SM4006WSSOD-323Rectifier, 2 pins, YFWRectifierSOD-3232 pinsYFW
- What it is
- Rectifier
- Maker
- YFW
- Package
- SOD-323
- Pins
- 2
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
SMA6J7.5ASMATVS diode, 2 pins, VishayTVS diodeSMA2 pinsVishay
- What it is
- TVS diode
- Maker
- Vishay
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMAF6J7.5ASMAFTVS diode, 2 pins, YFWTVS diodeSMAF2 pinsYFW
- What it is
- TVS diode
- Maker
- YFW
- Package
- SMAF
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
5 more parts have no package on record
RB168L100Schottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RB168L100DDSchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
S-LDTA114EET1GDigital transistor (PNP, resistors built in), LRCDigital transistor (PNP, resistors built in)Not recordedNot recordedLRC
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
SMA6F7.5ATVS diode, VishayTVS diodeNot recordedNot recordedVishay
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 600 W TVS diode, unidirectional
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMA6SF7.5ATVS diode, Formosa MicrosemiTVS diodeNot recordedNot recordedFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
NPN transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.