Skip to content

SMD code 6Bs

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

The last letter, s, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and 6B was searched.

122 parts are printed 6Bs

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • LMUN5112T1GSOT-323Digital transistor (PNP, resistors built in), 3 pins, LRCDigital transistor (PNP, resistors built in)SOT-3233 pinsLRC
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    LRC
    Package
    SOT-323
    Pins
    3
    Details
    Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • MM1Z 47SOD-123Zener diode, 2 pins, HottechZener diodeSOD-1232 pinsHottech
    What it is
    Zener diode
    Maker
    Hottech
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode, VZ 47 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MM1Z 47LSOD-123FZener diode, 2 pins, HottechZener diodeSOD-123F2 pinsHottech
    What it is
    Zener diode
    Maker
    Hottech
    Package
    SOD-123F
    Pins
    2
    Details
    Zener diode, VZ 47 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MM1Z47SOD-123Zener diode, 2 pins, HXYZener diodeSOD-1232 pinsHXY
    What it is
    Zener diode
    Maker
    HXY
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode, 27 V, 0.005 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MM1Z47WSOD-123Zener diode, 2 pins, HXYZener diodeSOD-1232 pinsHXY
    What it is
    Zener diode
    Maker
    HXY
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode, 22 V, 0.005 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MUN2112SOT-23Digital transistor (PNP, resistors built in), 3 pins, onsemiDigital transistor (PNP, resistors built in)SOT-233 pinsonsemi
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    onsemi
    Package
    SOT-23
    Pins
    3
    Details
    Digital Transistors (BRT) R1 = 22 k  , R2 = 22 k 
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • MUN5112SOT-323Digital transistor (PNP, resistors built in), 3 pins, onsemiDigital transistor (PNP, resistors built in)SOT-3233 pinsonsemi
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    onsemi
    Package
    SOT-323
    Pins
    3
    Details
    Digital Transistors (BRT) R1 = 22 k  , R2 = 22 k 
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • S-LBC817-25LT1GSOT-23NPN transistor, 3 pins, LRCNPN transistorSOT-233 pinsLRC
    What it is
    NPN transistor
    Maker
    LRC
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor, NPN, IC 500 mA, VCEO 45 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • S-LBC817-25LT1G-SSOT-23NPN transistor, 3 pins, LRCNPN transistorSOT-233 pinsLRC
    What it is
    NPN transistor
    Maker
    LRC
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor, NPN, IC 500 mA, VCEO 45 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • S-LBC817-25WT1GSOT-323NPN transistor, 3 pins, LRCNPN transistorSOT-3233 pinsLRC
    What it is
    NPN transistor
    Maker
    LRC
    Package
    SOT-323
    Pins
    3
    Details
    Bipolar transistor, NPN, IC 500 mA, VCEO 45 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • S-LMUN5112T1GSOT-323Digital transistor (PNP, resistors built in), 3 pins, LRCDigital transistor (PNP, resistors built in)SOT-3233 pinsLRC
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    LRC
    Package
    SOT-323
    Pins
    3
    Details
    Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • SBC817-25LSOT-23NPN transistor, 3 pins, onsemiNPN transistorSOT-233 pinsonsemi
    What it is
    NPN transistor
    Maker
    onsemi
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • SMBJ90CDSMBTVS diode, 2 pins, VishayTVS diodeSMB2 pinsVishay
    What it is
    TVS diode
    Maker
    Vishay
    Package
    SMB
    Pins
    2
    Details
    600 W TVS diode, bidirectional
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMBJ90DSMBTVS diode, 2 pins, VishayTVS diodeSMB2 pinsVishay
    What it is
    TVS diode
    Maker
    Vishay
    Package
    SMB
    Pins
    2
    Details
    600 W TVS diode, unidirectional
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 1 more part has no package on record

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

NPN transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.