Skip to content

SMD code 6Q

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 25 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BZD27B110P-MSOD-123FZener diode, 2 pins, VishayZener diodeSOD-123F2 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123F
    Pins
    2
    Details
    110 V Zener diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • DTA144TESOT-416Digital transistor (PNP, resistors built in), 3 pins, onsemiDigital transistor (PNP, resistors built in)SOT-4163 pinsonsemi
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    onsemi
    Package
    SOT-416
    Pins
    3
    Details
    50V, 100mA, PNP Bipolar Digital Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • MUN2238SOT-23Digital transistor (NPN, resistors built in), 3 pins, onsemiDigital transistor (NPN, resistors built in)SOT-233 pinsonsemi
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    onsemi
    Package
    SOT-23
    Pins
    3
    Details
    Digital Transistors (BRT) R1 = 2.2 k  , R2 =  k 
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • MUN5138SOT-323Digital transistor (PNP, resistors built in), 3 pins, onsemiDigital transistor (PNP, resistors built in)SOT-3233 pinsonsemi
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    onsemi
    Package
    SOT-323
    Pins
    3
    Details
    Digital Transistors (BRT) R1 = 2.2 k  , R2 =  k 
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • PPT3FD3906SOT-8833 pins, PrisemiNot recordedSOT-8833 pinsPrisemi
    What it is
    Not recorded
    Maker
    Prisemi
    Package
    SOT-883
    Pins
    3
    Details
    Bipolar transistor, 40 V, 0.2 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor.

  • PZS1116BESSOD-523Zener diode, 2 pins, PanjitZener diodeSOD-5232 pinsPanjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • SY28826DUCDFNLoad switch, SilergyLoad switchDFNNot recordedSilergy
    What it is
    Load switch
    Maker
    Silergy
    Package
    DFN
    Pins
    Not recorded
    Details
    5.5V, Low RDS(ON) Dual-Channel 6A Load Switch
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • DTA123TN3SOT-23Digital transistor (PNP, resistors built in), 3 pins, CYStekDigital transistor (PNP, resistors built in)SOT-233 pinsCYStek
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    CYStek
    Package
    SOT-23
    Pins
    3
    Details
    PNP digital (resistor-equipped) transistor, R1 2.2K, R2 None
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Digital transistor.

  • BZD27C68WSOD-123WZener diode, 2 pins, Fagor ElectronicaZener diodeSOD-123W2 pinsFagor Electronica
    What it is
    Zener diode
    Maker
    Fagor Electronica
    Package
    SOD-123W
    Pins
    2
    Details
    Zener diode: 64..72V, Zzt=25, Izt=10mA, 1W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • MMBFJ305SOT-233 pins, Texas InstrumentsNot recordedSOT-233 pinsTexas Instruments
    What it is
    Not recorded
    Maker
    Texas Instruments
    Package
    SOT-23
    Pins
    3
    Details
    equivalent J305
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • PMBT3906MSOT-8833 pins, NexperiaNot recordedSOT-8833 pinsNexperia
    What it is
    Not recorded
    Maker
    Nexperia
    Package
    SOT-883
    Pins
    3
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • R1210N261ASOT-23-55 pins, Nisshinbo Micro DevicesNot recordedSOT-23-55 pinsNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-23-5
    Pins
    5
    Details
    VR-IC: PWM step-up DC-DC converter, 2,6V, 35..100KHz
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • R3133Q24ECSOT-1434 pins, Nisshinbo Micro DevicesNot recordedSOT-1434 pinsNisshinbo Micro Devices
    What it is
    Not recorded
    Maker
    Nisshinbo Micro Devices
    Package
    SOT-143
    Pins
    4
    Details
    CMOS-IC: Voltage Detector 2,4V, MR, Reset Open drain output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • R5106N531ASOT-23-6Voltage supervisor, 6 pins, RicohVoltage supervisorSOT-23-66 pinsRicoh
    What it is
    Voltage supervisor
    Maker
    Ricoh
    Package
    SOT-23-6
    Pins
    6
    Details
    Voltage detector IC: 5.3V±1%, -Reset ODO, Inhibit
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 1 more part has no package on record

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Digital transistor

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 6Q

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 238 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.

2 identifications have been run against this marking.