  • FR106WSSOD-323Rectifier, 2 pins, RectronRectifier2 pinsRectron
    What it is
    Rectifier
    Maker
    Rectron
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Silicon diode.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • KIA7045ATVoltage supervisor, KECVoltage supervisorNot recordedKEC
      What it is
      Voltage supervisor
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • TCK22972GLoad switch, ToshibaLoad switchNot recordedToshiba
      What it is
      Load switch
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      2A, 25m Ω Load Switch IC with Slew Rate Control Driver
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Load switch.

    • AP7343D-31FS4-7BLDO regulator, Diodes IncorporatedLDO regulatorNot recordedDiodes Incorporated
      What it is
      LDO regulator
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 3.1V±1%, 300mA, +CE, CL
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • IXD5126N18A7R-GVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.8V±0.8%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127C39BNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.9V±0.8%, -Reset PPO, -MR, 100ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127N39GNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.9V±0.8%, +Reset ODO, -MR, 100ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • RP101K332DLDO regulator, RicohLDO regulatorNot recordedRicoh
      What it is
      LDO regulator
      Maker
      Ricoh
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, LN, 3.3V±0.8%, 300mA, +CE, CL
      Source
      Published code list

      Is it dead? The meter test is below: Voltage regulator.

    • RP500N144ADC-DC converter, RicohDC-DC converterNot recordedRicoh
      What it is
      DC-DC converter
      Maker
      Ricoh
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM st-dwn, 1.4V±24mV, 600mA, +CE, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • SRA2206EFAukNot recordedNot recordedAuk
      What it is
      Not recorded
      Maker
      Auk
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-pnp-Digi: Sw, 50V, 100mA, 150mW, 200MHz, R1/R2=4.7/47k
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • SRA2206UFAukNot recordedNot recordedAuk
      What it is
      Not recorded
      Maker
      Auk
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-pnp-Digi: Sw, 50V, 100mA, 200mW, 200MHz, R1/R2=4.7/47k
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • XC6126N18A7R-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.8V±0.8%, -Reset ODO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6127C39BNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.9V±0.8%, -Reset PPO, -MR, Rdt=100ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6127N39GNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.9V±0.8%, +Reset ODO, -MR, Rdt=100ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129C39G9R-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.9V±0.8%, +Reset PPO, Releasy Delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 6R

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.