SMD code 6S
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
47 parts are printed 6S
Not sure which one you have?
Answer up to 4 quick questions and these 47 parts are ranked, with a meter test that settles it. It works on a dead part too.
CPDVR105V0UA-HFDFNESD protection diode, ComchipESD protection diodeDFNNot recordedComchip
- What it is
- ESD protection diode
- Maker
- Comchip
- Package
- DFN
- Pins
- Not recorded
- Details
- 5 V unidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LBAT40-04LT1GSOT-23Schottky diode, 3 pins, LRCSchottky diodeSOT-233 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Schottky diode, VR 40 V, IF 0.35 A, VF Max 0.37 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LBAT40HT1GSOD-323Schottky diode, 2 pins, LRCSchottky diodeSOD-3232 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Schottky diode, VR 40 V, IF 0.35 A, VF Max 0.6 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LBAT40HT3GSOD-323Schottky diode, 2 pins, LeiditechSchottky diodeSOD-3232 pinsLeiditech
- What it is
- Schottky diode
- Maker
- Leiditech
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
MBRX260SOD-123FSchottky diode, 2 pins, Galaxy MicroelectronicsSchottky diodeSOD-123F2 pinsGalaxy Microelectronics
- What it is
- Schottky diode
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 2A, 60V, Surface Mount Schottky Barrier Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
MMBFJ113SOT-23N-channel MOSFET, 3 pins, onsemiN-channel MOSFETSOT-233 pinsonsemi
- What it is
- N-channel MOSFET
- Maker
- onsemi
- Package
- SOT-23
- Pins
- 3
- Details
- N-Channel Switch J111, J112, J113
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
MMSD71RKSOD-123Switching diode, 2 pins, onsemiSwitching diodeSOD-1232 pinsonsemi
- What it is
- Switching diode
- Maker
- onsemi
- Package
- SOD-123
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
PMBFJ176SOT-23JFET, 3 pins, NXPJFETSOT-233 pinsNXP
- What it is
- JFET
- Maker
- NXP
- Package
- SOT-23
- Pins
- 3
- Details
- 1 Product profile
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: JFET.
S-LBAT40HT1GSOD-323Schottky diode, 2 pins, LRCSchottky diodeSOD-3232 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Schottky diode, VR 40 V, IF 0.35 A, VF Max 0.6 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
S-LBAT40HT3GSOD-323Schottky diode, 2 pins, LeiditechSchottky diodeSOD-3232 pinsLeiditech
- What it is
- Schottky diode
- Maker
- Leiditech
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SD103AWSSOD-323Schottky diode, 2 pins, VishaySchottky diodeSOD-3232 pinsVishay
- What it is
- Schottky diode
- Maker
- Vishay
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SM260FLSOD-123FSchottky diode, 2 pins, SeCoSSchottky diodeSOD-123F2 pinsSeCoS
- What it is
- Schottky diode
- Maker
- SeCoS
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
TMBRX260SOD-123FSchottky diode, 2 pins, Galaxy MicroelectronicsSchottky diodeSOD-123F2 pinsGalaxy Microelectronics
- What it is
- Schottky diode
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 2A, 60V, Surface Mount Schottky Barrier Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
UMZ27NUMSOT-323ESD protection diode, 3 pins, ROHMESD protection diodeSOT-3233 pinsROHM
- What it is
- ESD protection diode
- Maker
- ROHM
- Package
- SOT-323
- Pins
- 3
- Details
- Transient Voltage Suppressor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
1 more part has no package on record
SGM11102GYXGG6G6 pins, SG MicroNot recordedNot recorded6 pinsSG Micro
- What it is
- Not recorded
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 6
- Details
- SPDT Switch for High Power Applications
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
JFET
Ohms range for drain to source, diode range for the gate, part lifted.
Working, it reads
Drain to source conducts both ways at a few hundred ohms, depending on the part, and some meters beep on it. The gate reads one junction to drain and to source, about 0.6 to 0.7 V, and open the other way.
Dead, it reads
- The gate the same both ways to drain or source, near 0 V with a continuous beep: gate shorted.
- Drain to source open: the channel has failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- Drain to source resistance varies from part to part. An identical part elsewhere on the board shows what is normal.
- Watch for:
- A good channel can beep like a short between drain and source. That is normal; the gate junction says whether it has failed.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 6S
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 514 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.