SMD code 6Z
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
37 parts are printed 6Z
Not sure which one you have?
Answer up to 4 quick questions and these 37 parts are ranked, with a meter test that settles it. It works on a dead part too.
MA373SOD-1232 pins, PanNot recordedSOD-1232 pinsPan
- What it is
- Not recorded
- Maker
- Pan
- Package
- SOD-123
- Pins
- 2
- Details
- C-diode: UHF-Tuning, 32V, 0,84pF(25V)
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
MM3Z4V3BWSOD-323Zener diode, 2 pins, Tak Cheong SemiconductorZener diodeSOD-3232 pinsTak Cheong Semiconductor
- What it is
- Zener diode
- Maker
- Tak Cheong Semiconductor
- Package
- SOD-323
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
MMBF170SOT-233 pins, Fairchild SemiconductorNot recordedSOT-233 pinsFairchild Semiconductor
- What it is
- Not recorded
- Maker
- Fairchild Semiconductor
- Package
- SOT-23
- Pins
- 3
- Details
- equivalent BS170
- Source
- Published code list
Is it dead? The meter test is below: This part.
MMBF170LT1SOT-233 pins, onsemiNot recordedSOT-233 pinsonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- SOT-23
- Pins
- 3
- Details
- N-Channel MOSFET
- Source
- Published code list
Is it dead? The meter test is below: N-channel MOSFET.
R1210N261DSOT-23-55 pins, Nisshinbo Micro DevicesNot recordedSOT-23-55 pinsNisshinbo Micro Devices
- What it is
- Not recorded
- Maker
- Nisshinbo Micro Devices
- Package
- SOT-23-5
- Pins
- 5
- Details
- VR-IC: PWM step-up DC-DC converter, 2,6V, 180KHz
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
SMZ2512SOD-123FZener diode, 2 pins, EICZener diodeSOD-123F2 pinsEIC
- What it is
- Zener diode
- Maker
- EIC
- Package
- SOD-123F
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
TCMM3Z4V3BSOD-3232 pins, TacNot recordedSOD-3232 pinsTac
- What it is
- Not recorded
- Maker
- Tac
- Package
- SOD-323
- Pins
- 2
- Details
- Z-diode: 4.3V±2%, Izt=5mA, Zzt=84Ω, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
8 more parts have no package on record
IXD5127N53GNRVoltage supervisor, IXYSVoltage supervisorNot recordedNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.3V±0.8%, +Reset ODO, -MR, 100ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
RP500N204ADC-DC converter, RicohDC-DC converterNot recordedNot recordedRicoh
- What it is
- DC-DC converter
- Maker
- Ricoh
- Package
- Not recorded
- Pins
- Not recorded
- Details
- DC/DC voltage converter IC: PWM st-dwn, 2.0V±1.5%, 600mA, +CE, CL
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
UNR911CJPanNot recordedNot recordedNot recordedPan
- What it is
- Not recorded
- Maker
- Pan
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Si-pnp-Digi: Sw, 50V, 100mA, 125mW, 80MHz, R2=47k
- Source
- Published code list
Is it dead? The meter test is below: This part.
XC6126N25A7R-GVoltage supervisor, TorexVoltage supervisorNot recordedNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 2.5V±0.8%, -Reset ODO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6127C53BNRVoltage supervisor, TorexVoltage supervisorNot recordedNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.3V±0.8%, -Reset PPO, -MR, Rdt=100ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6127N53GNRVoltage supervisor, TorexVoltage supervisorNot recordedNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.3V±0.8%, +Reset ODO, -MR, Rdt=100ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6129C53G9R-GVoltage supervisor, TorexVoltage supervisorNot recordedNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.3V±0.8%, +Reset PPO, Releasy Delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6129C53GNR-GVoltage supervisor, TorexVoltage supervisorNot recordedNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.3V±0.8%, +Reset PPO, Releasy Delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.