SMD code 76 in SOT-323
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
10 parts in SOT-323 are printed 76
Not sure which one you have?
Answer up to 4 quick questions and these 25 parts are ranked, with a meter test that settles it. It works on a dead part too.
1PS70SB16SOT-323Schottky diode, 3 pins, NexperiaSchottky diode3 pinsNexperia
- What it is
- Schottky diode
- Maker
- Nexperia
- Package
- SOT-323
- Pins
- 3
- Details
- Dual Schottky barrier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
2SA1576ARSOT-323PNP transistor, 3 pins, onsemiPNP transistor3 pinsonsemi
- What it is
- PNP transistor
- Maker
- onsemi
- Package
- SOT-323
- Pins
- 3
- Details
- Bipolar transistor, 50 V, 0.15 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
BAS70-06WSOT-323Schottky diode, 3 pins, DiotecSchottky diode3 pinsDiotec
- What it is
- Schottky diode
- Maker
- Diotec
- Package
- SOT-323
- Pins
- 3
- Details
- SMD Small Signal Schottky Diodes
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
DTA144WU3SOT-323Digital transistor (PNP, resistors built in), 3 pins, ROHMDigital transistor (PNP, resistors built in)3 pinsROHM
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- ROHM
- Package
- SOT-323
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
DTA144WUASOT-323Digital transistor (PNP, resistors built in), 3 pins, ROHMDigital transistor (PNP, resistors built in)3 pinsROHM
- What it is
- Digital transistor (PNP, resistors built in)
- Maker
- ROHM
- Package
- SOT-323
- Pins
- 3
- Details
- PNP -100mA -50V Digital Transistors (Bias Resistor Built-in Transistors)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
GSBAS70W-06SOT-323Schottky diode, 3 pins, Good-ArkSchottky diode3 pinsGood-Ark
- What it is
- Schottky diode
- Maker
- Good-Ark
- Package
- SOT-323
- Pins
- 3
- Details
- Schottky diode, 70 V, 70 mA
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
2SA1576ART1SOT-3233 pins, onsemiNot recorded3 pinsonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- SOT-323
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
AP8822N-46GTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisor3 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 4.6V±2%, -Reset ODO, Rdt=200ms, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-46PTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisor3 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 4.6V±2%, -Reset ODO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
EC95810N46C1NSOT-323Voltage supervisor, 3 pins, E-CMOSVoltage supervisor3 pinsE-CMOS
- What it is
- Voltage supervisor
- Maker
- E-CMOS
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 4.6V±2%, -Reset ODO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
5 more parts have no package on record. Nothing rules them out, so they stay.
SGM892B-2.9XUDH4GVoltage supervisor, 4 pins, SG MicroVoltage supervisor4 pinsSG Micro
- What it is
- Voltage supervisor
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 4
- Details
- Standard CMOS Voltage Detector ICs
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
TPS22913CYZVLoad switch, 4 pins, Texas InstrumentsLoad switch4 pinsTexas Instruments
- What it is
- Load switch
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- Ultra-small, Low On Resistance Load Switch With Controlled Turn-on
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Load switch.
AP8822N-46GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.6V±2%, -Reset ODO, 200ms Rt delay, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-46GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.6V±2%, -Reset ODO, 200ms Rt delay, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-46PIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.6V±2%, -Reset ODO, 200ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PNP transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Load switch
Voltage, board powered, black probe on ground.
Working, it reads
Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.
Dead, it reads
- Output at the input voltage while switched off: the pass element has shorted.
- Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
- On the board:
- An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 76
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 1 more part.
Did you find your part?
Open this in the search to correct a character or try another package.